Gas Connection Installation Instructions - Empire Comfort Systems PV-28SV50-BN-1 Owner's Manual

Power-vent high-efficiency fireplace with bay window
Hide thumbs Also See for PV-28SV50-BN-1:
Table of Contents

Advertisement

GAS CONNECTION INSTALLATION INSTRUCTIONS

GAS CONNECTION (Line Supply)
A 3/8" Flair gas line connection is supplied in the heater
GAS SUPPLY LINE TO HEATER
a.
Remove rubber grommet from back panel and pull out flex line through back panel.
b.
Connect gas supply line to flexible gas hose. Ensure that flexible gas hose is not kinked after fitting gas supply line.
c.
After gas supply line has been brought through from rear of heater, place rubber grommet supplied over gas line.
Note:
The gas supply line to the heater must be installed under conditions which will allow for easy removal of the heater from its
location for servicing of the heater. For fireplace insert installations, incorporate either a copper loop into the supply line or flexible hose
being used for the gas supply to the heater to allow for easy removal of the appliance.
Note:
Under no circumstances should the gas supply line to the appliance be installed under conditions, which would not allow for
easy removal of the appliance to carry out routine inspection and service to the appliance.
Page 34
FLEXIBLE GAS
LINE
Figure 39
24820-2-0709

Advertisement

Table of Contents
loading

Table of Contents