Kohler Command PRO ECH630 Service Manual page 93

Command pro horizontal crankshaft
Hide thumbs Also See for Command PRO ECH630:
Table of Contents

Advertisement

Test 4. Solenoid Hold-In Coil/Contact Continuity.
Use an ohmmeter set to the audible or Rx2K scale, and
connect the two ohmmeter leads to the two large post
terminals. Perform the preceding test (3) and check
for continuity. See Figure 7-40. The meter should
indicate continuity, if no continuity is indicated the
solenoid should be replaced. Repeat test several times
to confi rm condition.
Electrical System and Components
Plunger
Pushed "In"
12 volt Test Leads
Figure 7-40. Testing Hold-In Coil/Solenoid Contact
Continuity.
Section 7
VOM Meter
Leads
7.17
7