Flushing - Graco 233889 Instructions Manual

Xtr airless spray gun a series
Table of Contents

Advertisement

Flushing

WARNING
Read warnings, page 3.
Flush pump and gun before fluid can dry in it. If avail-
able, use flushing procedure provided in your pump or
sprayer manual instead of this procedure.
1.
Follow Pressure Relief Procedure, page 6.
Engage trigger lock.
T12178A
2.
Remove tip guard and spray tip. Clean with sol-
vent. See page 9.
3.
Put the pump intake in a grounded pail of compati-
ble solvent.
309523D
4.
Start pump at its lowest pressure.
5.
Disengage trigger lock, then trigger gun into the
paint pail. When solvent appears, release trigger.
6.
Trigger gun into solvent pail. Circulate fluid until
system is thoroughly flushed.
7.
Follow Pressure Relief Procedure, page 6.
Engage trigger lock.
T12178A
Flushing
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

234032309523d