Fan Air Adjustment Valve Repair - Graco 222625 Instructions-Parts List Manual

Electrostatic air spray gun 65 kv, high conductivity, manual gun b series
Table of Contents

Advertisement

Fan Air Adjustment Valve Repair

1. Prepare the gun for service as instructed on page
24.
2. Place a wrench on the flats of the valve housing
and remove it from the handle. See Fig. 20.
NOTE: The fan air valve (43) can be replaced as an
assembly or as individual parts.
To disassemble the fan valve:
3. Remove the retaining ring (43b). Rotate the air
adjustment knob (43c) counterclockwise until it is
disengaged from the valve housing threads (43d).
Pull the adjustment knob out of the valve housing.
4. Clean all the parts and inspect them for wear or
damage.
5. When reassembling the fan air valve (43), lubricate
the o-rings (43e) and the adjustment knob threads
(43c) with petroleum jelly.
6. After the retaining ring (43b) is installed on the
adjustment knob (43c), back the adjustment knob
out of the valve housing (43d) until it bottoms out
against the retaining ring.
7. Apply PTFE paste to the threads of the valve
housing (43d) and install it in the handle. Torque
the housing to 10 to 12 in-lb (1.1 to 1.4 NSm).
Service

Lubricate o-rings (43e) and top knob threads (43c) with petro-
leum jelly

Apply PTFE paste to the valve housing threads (43d); Torque
to 10–12 in-lb (1.1–1.4 NSm)
Fig. 20
DETAIL

43d
43b
43c

43e
43
308018

31

Advertisement

Table of Contents
loading

This manual is also suitable for:

223451308018Pro 3500hcPro 3500hc 222625Pro 3500hc 223451

Table of Contents