Table of Contents

INTRODUCTION..................................................................................................................................2
PACKAGE CONTENTS....................................................................................................................... 2
INTENDED USE................................................................................................................................... 2
BLOOD PRESSURE CLASSIFICATION FOR ADULTS......................................................................2
CONTRAINDICATION......................................................................................................................... 3
PARTS AND DISPLAY INDICATORS................................................................................................. 3
SET UP REQUIREMENTS................................................................................................................... 3
SET UP PROCEDURES....................................................................................................................... 4
MEASUREMENT PROCEDURES.........................................................................................................5
SPECIFICATIONS................................................................................................................................ 6
GENERAL SAFETY AND PRECAUTIONS......................................................................................... 7
BATTERY HANDLING AND USAGE.................................................................................................. 8
TROUBLESHOOTING......................................................................................................................... 9
CARE AND MAINTENANCE............................................................................................................. 10
WARRANTY INFORMATION........................................................................................................... 10
EXPLANATION OF SYMBOLS......................................................................................................... 11
IMPORTANT INFORMATION REQUIRED BY THE FCC................................................................12
OTHER STANDARDS AND COMPLIANCES....................................................................................12
ELECTROMAGNETIC COMPATIBILITY INFORMATION...............................................................13
1

Advertisement

Table of Contents
loading

Summary of Contents for iHealth BP7

  • Page 1: Table Of Contents

    Wireless Blood Pressure Wrist Monitor (BP7) OWNER’S MANUAL Table of Contents INTRODUCTION..........................2 PACKAGE CONTENTS........................2 INTENDED USE........................... 2 BLOOD PRESSURE CLASSIFICATION FOR ADULTS..............2 CONTRAINDICATION......................... 3 PARTS AND DISPLAY INDICATORS....................3 SET UP REQUIREMENTS........................3 SET UP PROCEDURES........................4 MEASUREMENT PROCEDURES......................5 SPECIFICATIONS..........................
  • Page 2: Wireless Blood Pressure Wrist Monitor (Bp7)

    INTRODUCTION Thank you for selecting the iHealth Wireless Blood Pressure Wrist Monitor. The iHealth Wireless Blood Pressure Wrist Monitor is a fully automatic wrist cuff blood pressure monitor that uses the oscillometric principle to measure your blood pressure and pulse rate. The monitor works with your mobile devices to test, track and share vital blood pressure data.
  • Page 3: Contraindication

    Wireless Blood Pressure Wrist Monitor. PARTS AND DISPLAY INDICATORS SET UP REQUIREMENTS The iHealth Wireless Blood Pressure Wrist Monitor is designed to be used with the following iPod touch, iPhone and iPad models: iPod touch (5th generation) iPod touch (4th generation)
  • Page 4: Set Up Procedures

    Turn Bluetooth "On" under the "Settings" Menu on the iOS device. Wait until the model name printed on the monitor, (i.e."BP7 xxxxxx") and "Not Paired"appear in the Bluetooth menu, and select the model name "BP7 xxxxxx" to pair and connect. The Bluetooth indicator will remain steady upon successful connection.
  • Page 5: Measurement Procedures

    2. Place your hand palm-side up in front of you and wrap the cuff around a bare wrist 1-2cm above the wrist joint. If the monitor is correctly placed, iHealth logo will be facing upright. 3. The middle of the cuff should be at the level of the right atrium of your heart.
  • Page 6: Specifications

    ATTENTION: You can stop the measurement process at any time by pressing and holding the "START/STOP" button for 2 seconds. SPECIFICATIONS 1. Product name: Wireless Blood Pressure Wrist Monitor 2. Model: BP7 3. Classification: Internally powered;Type BF applied part;IPX0, No AP or APG;Continuous operation 4. Machine size: approx.2.8"×2.9"×0.7"(72mm×74mm×17.6mm) 5.
  • Page 7: General Safety And Precautions

    GENERAL SAFETY AND PRECAUTIONS 1. Read all of the information in the Owner’s Manual and other provided instructions before operating the unit. 2. Consult your physician for any of the following situations: a)The application of the cuff over a wound or inflamed area. b)The application of the cuff on any limb with intravascular access or therapy, or an arterio-venous (A-V) shunt.
  • Page 8: Battery Handling And Usage

    range specified in part SPECIFICATIONS, the app will immediately display a technical alarm on screen. In this case, consult a physician or ensure that proper measurement procedures are followed. The technical alarm is preset in the factory and cannot be adjusted or inactivated. This technical alarm is assigned as low priority according to IEC 60601-1-8.The technical alarm is non-latching and does not need to be reset.
  • Page 9: Troubleshooting

    The monitor, cable, battery and cuff must be disposed of according to local regulations at the end of their usage. Note: Battery life and charge cycles vary by use and settings. TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Low Battery Battery is less than 25% Charge the battery Retest, make sure your blood Blood pressure is outside...
  • Page 10: Care And Maintenance

    Battery replacement should only be performed by a qualified iHealth technician. To do otherwise will void your warranty and possibly damage your unit. Cuff replacement should only be performed by a qualified iHealth technician. To do otherwise will possibly damage your Unit.
  • Page 11: Explanation Of Symbols

    U.S. and other countries. The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by iHealth Lab Inc. is under license. Other trademarks and trade names are those of their respective owners.
  • Page 12: Important Information Required By The Fcc

    (2)this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by iHealth Lab Inc. would void the user’s authority to operate the product. Note: This product has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
  • Page 13: Electromagnetic Compatibility Information

    IEC 60601-1:2006 (Medical electrical equipment – Part 1: General requirements for safety); IEC 60601-1-2:2007 (Medical electrical equipment – Part 1: General requirements for safety; Collateral Standard-Electromagnetic compatibility - Requirements and tests); EN 1060-1: 1995 + A1: 2002 + A2: 2009 (Non-invasive sphygmomanometers - Part 1: General requirements);...
  • Page 14 the relative humidity should be at least 30 %. Electrical fast ± 2 kV for power ± 2 kV for power Mains power quality should be transient/burst supply lines supply lines that of a typical commercial or IEC 61000-4-4 hospital environment. Surge ±...
  • Page 15 Radiated RF 3 V/m 80 MHz to 3 V/m 80 MHz to 800 MHz IEC 61000-4-3 2.5 GHz 800 MHz to 2.5 GHz Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m).
  • Page 16 0.12 0.12 0.23 0.01 0.38 0.38 0.73 For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be determined using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.

Table of Contents