iHealth BP5 Owner's Manual

iHealth BP5 Owner's Manual

Wireless blood pressure monitor
Hide thumbs Also See for BP5:

Advertisement

iHealthâ„¢
Wireless Blood Pressure Monitor (BP5)
OWNER'S MANUAL

Table of Contents

INTRODUCTION................................................................................................................................. 2
PACKAGE CONTENTS........................................................................................................................2
INTENDED USE................................................................................................................................. 2
BLOOD PRESSURE CLASSIFICATION FOR ADULTS.............................................................. 2
CONTRAINDICATION........................................................................................................................3
PARTS AND DISPLAY INDICATORS...........................................................................................3
SET UP REQUIREMENTS................................................................................................................ 3
SET UP PROCEDURES..................................................................................................................... 3
MEASUREMENT PROCEDURES......................................................................................................... 4
SPECIFICATIONS............................................................................................................................ 6
GENERAL SAFETY AND PRECAUTIONS...................................................................................... 7
BATTERY HANDLING AND USAGE............................................................................................... 9
TROUBLESHOOTING.......................................................................................................................... 9
CARE AND MAINTENANCE............................................................................................................11
WARRANTY INFORMATION............................................................................................................11
EXPLANATION OF SYMBOLS.......................................................................................................12
IMPORTANT INFORMATION REQUIRED BY THE FCC......................................................... 13
OTHER STANDARDS AND COMPLIANCES................................................................................. 13
ELECTROMAGNETIC COMPATIBILITY INFORMATION......................................................... 14

Advertisement

Table of Contents
loading

Summary of Contents for iHealth BP5

  • Page 1: Table Of Contents

    Wireless Blood Pressure Monitor (BP5) OWNER’S MANUAL Table of Contents INTRODUCTION..........................2 PACKAGE CONTENTS........................2 INTENDED USE..........................2 BLOOD PRESSURE CLASSIFICATION FOR ADULTS.............. 2 CONTRAINDICATION........................3 PARTS AND DISPLAY INDICATORS...................3 SET UP REQUIREMENTS........................ 3 SET UP PROCEDURES........................3 MEASUREMENT PROCEDURES......................4 SPECIFICATIONS..........................
  • Page 2: Introduction

    INTRODUCTION Thank you for selecting the iHealth Wireless Blood Pressure Monitor. The iHealth Wireless Blood Pressure Monitor is a fully automatic arm cuff blood pressure monitor that uses the oscillometric principle to measure your blood pressure and pulse rate. The monitor works with your mobile device to test, track and share vital blood pressure data.
  • Page 3: Contraindication

    It is not recommended for people with serious arrhythmia to use this Wireless Blood Pressure Monitor. PARTS AND DISPLAY INDICATORS SET UP REQUIREMENTS The iHealth Wireless Blood Pressure Monitor is designed to be used with the following iPod touch, iPhone and iPad models: iPod touch (5th generation) iPod touch (4th generation)
  • Page 4: Measurement Procedures

    • Turn Bluetooth "On" under the "Settings" menu on the iOS device. • Wait until the model name printed on the monitor, (i.e. "BP5 xxxxxx") and "Not Paired" appear in the Bluetooth menu, and select the model name "BP5 xxxxxx"...
  • Page 5 Lying Down During Measurement a. Lie on your back. b. Place your arm straight along your side with your hand palm-side c. The cuff should be placed at the same level as your heart. Note: Blood pressure can be affected by the position of the cuff and your physiologic condition.
  • Page 6: Specifications

    “START/STOP” button for 2 seconds. SPECIFICATIONS 1. Product name: Wireless Blood Pressure Monitor 2. Model: BP5 3. Classification: Internally powered, Type BF applied part, IPX0, No AP or APG, Continuous operation 4. Machine size: approx. 5.7”× 2.3”×1.2”(145mm × 58mm ×30mm) 5.
  • Page 7: General Safety And Precautions

    measurement 8. Memory volume: 120 times with time and date stamp (off-line measurement only) 9. Power: DC: 5.0V 1.0A, Battery: 1*3.7V Li-ion 400mAh 10. Measurement range: Cuff pressure: 0-300 mmHg Systolic: 60-260 mmHg Diastolic: 40-199 mmHg Pulse rate: 40-180 beats/minute 11.
  • Page 8 device be set in Airplane mode during measurement to avoid strong magnetism interference. 6. If Irregular Heartbeat (IHB) is detected during the measurement procedure, the IHB symbol will be displayed. Under this condition, the Wireless Blood Pressure Monitor can keep functioning, but the results may be inaccurate.
  • Page 9: Battery Handling And Usage

    BATTERY HANDLING AND USAGE • When the monitor is connected to the iOS device, the battery volume will be displayed on the iOS device. If the power is less than 25%, please charge the battery. The monitor will not work until the battery has enough power.
  • Page 10 The cuff does not inflate properly or Review the cuff application pressure falls instructions and retest quickly during test Irregular heartbeat It is inappropriate for (arrhythmia) people with serious arrhythmia to use this monitor. Check with physician. The cuff was not Review the cuff application properly applied instructions and retest...
  • Page 11: Care And Maintenance

    To do otherwise will possibly damage your unit. WARRANTY INFORMATION The iHealth Wireless Blood Pressure Monitor is warranted to be free from defects in materials and workmanship within one year from the date of purchase when used in accordance with the provided instructions.
  • Page 12: Explanation Of Symbols

    Apple Inc., registered in the U.S. and other countries. The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by iHealth Lab Inc. is under license. Other trademarks and trade names are those of their respective owners.
  • Page 13: Important Information Required By The Fcc

    (2)this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by iHealth Lab Inc. would void the user’s authority to operate the product. Note: This product has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
  • Page 14: Electromagnetic Compatibility Information

    IEC 60601-1-2:2007 (Medical electrical equipment – Part 1: General requirements for safety; Collateral Standard-Electromagnetic compatibility - Requirements and tests); EN 1060-1: 1995 + A1: 2002 + A2: 2009 (Non-invasive sphygmomanometers - Part 1: General requirements); EN 1060-3: 1997 + A1: 2005 + A2: 2009 (Non-invasive sphygmomanometers - Part 3: Supplementary requirements for electro-mechanical blood pressure measuring systems);...
  • Page 15 ic discharge ± 8 kV air ± 8 kV air concrete or ceramic tile. If (ESD) floors are covered with synthetic material, the 61000-4-2 relative humidity should be at least 30 %. Electrical ± 2 kV for power ± 2 kV for power Mains power quality should be fast supply lines...
  • Page 16 recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance: Conducted RF 3 Vrms 150 61000-4-6 kHz to 80 MHz Radiated RF 3 V/m 80 MHz 3 V/m 80 MHz to 800 MHz to 2.5 GHz 61000-4-3 800 MHz to 2.5 GHz...
  • Page 17 portable and mobile RF communications equipment and the Wireless Blood Pressure Monitor The Wireless Blood Pressure Monitor is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the Wireless Blood Pressure Monitor can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the MONITOR as recommended below, according to the maximum output power of the...

Table of Contents