Electrolux EFC 929 User Manual page 7

Electrolux cooker hood
Table of Contents

Advertisement

Mounting the cooker hood - Fig. 6
Preliminary information for installation of the hood:
Disconnect the hood during electrical connection, by turning the home mains switch off.
• Using a pencil, draw a line on the wall, extending up to the ceiling, to mark the centre. This will facilitate installation.
• Rest the drilling template against the wall (1) : the vertical centre line printed on the drilling template must
correspond to the centre line drawn on the wall, and the bottom edge of the drilling template must correspond to the
bottom edge of the hood: bear in mind that, when installation is complete, the underside of the hood must be at least
60 cm above the cooker top in the case of electric cookers, and at least 75 cm above the cooker top in the case of gas
or mixed cookers.
• Mark the two holes and drill them (2), remove the drilling template, insert 2 wall plugs (3) , hooks (4) and fix them
with screws (5).
• Hang the hood on the hooks (6).
• Adjust the distance of the hood from the wall, adjust the horizontal position of the hood (7).
• From inside the suction unit, use a pencil to mark the 2 holes to be used for final fixing of the hood (8).
• Remove the hood from the bracket.
• Drill at the point marked (2 x Ø8mm ) and insert 2 wall plugs (9).
• Hook the hood onto the bottom bracket.
• Fix the hood into its final position on the wall using 2 x 5x45mm screw (10 - ABSOLUTELY ESSENTIAL).
• Rest the chimney support bracket (13) against the wall, touching the ceiling. Use the support bracket as a drilling
template (the small slot formed on the support must coincide with the line drawn on the wall as above) and mark 2
holes with a pencil, dril the holes (11 - Ø8mm), insert 2 wall plugs (12).
• Fix the chimney support bracket to the wall using two 5x45mm screws (14).
• Connect a pipe (pipe and pipe clamps not provided, to be purchased separately) for discharge of fumes to the
connection ring located over the suction motor unit (16).
If the hood is to be used in ducting version, the other end of the pipe must be connected to a device expelling the
fumes to the outside. If the
hood is to be used in filter
version, fix deflector (15F)
to the chimney support
bracket using 2 screws,
and connect the other end
of the pipe to the
connection ring on
deflector.
• Make the electrical
connections.
• Apply the chimney stacks
and fasten them at the top
to the chimney support
using 2 screws (17).
• Slide the bottom section
of the chimney down until
it completely covers the
suction unit and slots into
the housing provided on
top of the hood (18).
Fig. 6