Electrical Connection - AEG 95751 Operating And Installation Manual

Gas hob
Table of Contents

Advertisement

Electrical Connection

The appliance is designed to be connected to 230 V monophase electricity supply.
The connection must be carried out in compliance with the laws and regulations in force.
Before the appliance is connected:
1) check that the main fuse and the domestic installation can support the load (see the rating label);
2) check that the power supply is properly earthed in compliance with the current rules;
3) check the socket or the double pole switch used for the electrical connection can be easily
reached with the appliance built in the forniture unit.
The appliance is supplied with a connection cable. This has to be provided with a proper plug, able
to support the load marked on the identification plate. To connect the plug to the cable, follow the
recommendation given in Fig. 5. The plug has to be fitted in a proper socket.
If connecting the appliance directly to the electric system, it is necessary that you install a double pole
switch between the appliance and the electricity supply, with a minimum gap of 3 mm. between the
switch contacts and of a type suitable for the required load in compliance with the current rules.
The connection cable has to be placed in order that, in each part, it cannot reach a temperature higher
than 90°C.
The brown coloured phase cable (fitted in the terminal
block contact marked with "L") must always be connected
to the network phase.
Replacement of the voltage
cable
The connection of the voltage cable to the appliance's
terminal block is of type "Y". This means that its
replacement requires the specific equipment of a
technician. In this case, only cable type H05V2V2-F
T90 must be used. The cable section must be suitable
to the voltage and the working temperature. The yellow/
green earth wire must be approximately 2 cm. longer
than the phase wires (Fig. 5).
To open the terminal block and reach the terminals,
proceed as follows:
insert the point of a screwdriver into the visible
protrunding part of the terminal block;
exert a light pressure and lift (Fig. 5-b)
46
Fig. 5
Earth (yellow/green)
Fig.5-b
Neutral
FO 0257