TROUBLESHOOTING
Most treadmill problems can be solved by following the steps below. Find the symptom that applies, and
follow the steps listed. If further assistance is needed, please call our Customer Service Department.
PROBLEM: The power does not turn on
SOLUTION: a. Make sure that the power cord is plugged into a properly earthed outlet. (See page 7.) If an exten-
sion cord is needed, use only a 3-conductor, 1 mm
ft.).
b. After the power cord has been plugged in, make sure that the key is fully inserted into the console.
c. Check the circuit breaker located on the treadmill
frame near the power cord. If the switch protrudes
as shown, the circuit breaker has tripped. To reset
the circuit breaker, wait for five minutes and then
press the switch back in.
PROBLEM: The power turns off during use
SOLUTION: a. Check the circuit breaker located on the treadmill frame near the power cord (see the drawing
above). If the circuit breaker has tripped, wait for five minutes and then press the switch back in.
b. Make sure that the power cord is plugged in. If the power cord is plugged in, unplug it, wait for
five minutes, and then plug it back in.
c. Remove the key from the console. Reinsert the key fully into the console.
d. If the treadmill still will not run, please call our Customer Service Department.
PROBLEM: The displays of the console do not function properly
SOLUTION: a. UNPLUG THE POWER CORD. Check the batteries in the console. If the batteries need to be re-
placed, see BATTERY INSTALLATION on page 8. Most problems are the result of drained bat-
teries.
b. Remove the key from the console and UNPLUG THE POWER CORD. Remove the screws from
the hood, and carefully remove the hood.
Locate the Reed Switch (44) and the Magnet (45) on
the left side of the Pulley (50). Turn the Pulley until the
Magnet is aligned with the Reed Switch. Make sure
that the gap between the Magnet and the Reed
Switch is about 3 mm (1/8 in.). If necessary, loosen
the Screw (33) and move the Reed Switch slightly.
Retighten the Screw. Re-attach the hood, and run the
treadmill for a few minutes to check for a correct
speed reading. Reattach the Resistance Knob.
2
(14-gauge) cord that is no longer than 1.5 m (5
c
Tripped
12
Reset
3 mm
44
45
33
Top
View
50
Need help?