Lp Tank Information; Connecting The Lp Tank - Weber Performer Touch-N-Go Ignition Owner's Manual

Gas ignition system
Table of Contents

Advertisement

Connecting the LP tank

WARNING: Make sure LP tank valve is closed.
Close by turning clockwise.
You will need: filled LP tank, a soap and water
solution and a rag or brush to apply it.
Lift LP tank onto tank holder.
Slide back the collar of the quick disconnect on the tank
valve. Figure 10 (a). Push the male fitting of the regulator
into the quick disconnect, and maintain
pressure. Slide the collar closed. Figure 10 (b). If it does
not engage or lock, repeat procedure. Gas will not flow
unless the quick disconnect is properly engaged.
Male fitting
Regulator
(b)
Quick disconnect
engaged
Figure 10
Mix soap and water.
Open the tank valve.
DANGER
Do not use an open flame to check for gas
leaks. Be sure there are no sparks or open
flames in the area while you check for leaks.
This will result in a fire or explosion which
can cause serious bodily injury or death
and damage to property.
WARNING: You should check for gas leaks every
time you disconnect and reconnect a gas fitting.
Note - Since some leak test solutions, including soap
and water, may be slightly corrosive, all connections
should be rinsed with water after checking for leaks.
To perform leak checks: Turn test valve to the CLOSED
position. Figure 11. Turn tank valve ON
(counterclockwise). Check for leaks by wetting the
connections with the soap and water solution and
watching for bubbles.
Quick disconnect
retracted
(a)
Collar
Check the following connections, as shown in figure 11:
a) Test valve to regulator connection.
b) Quick disconnect fitting to LP tank connection.
If bubbles occur, or if a bubble enlarges, the connection
is leaking, turn OFF the gas at LP tank.
If the leak is at connection a) DO NOT OPERATE THE
BARBECUE. Contact your dealer.
Test valve in
CLOSED position
If the leak is at connection b), disconnect and reconnect
the quick disconnect fitting. Turn the gas back on and
recheck with the soap and water solution.
WARNING: If leak persists after tightening the
connection, turn OFF the gas at LP tank. DO NOT
OPERATE THE BARBECUE. Contact your dealer.
After completing the leak checks:
a) Turn the LP tank valve OFF (clockwise) and rinse
connections with water.
b) Turn the test valve to the OPEN position (parallel to
the hose). Figure 11.
LP Tank
The LP tank manufacturer is responsible for the
materials, workmanship and performance of the tank.
If the tank has a defect, malfunctions, or you have a
question regarding the tank, call the tank manufacturer's
customer service center. The phone number is on the
warning decal which is permanently attached to the tank. If
the tank manufacturer has not resolved the issue to your
satisfaction, then call Weber-Stephen Products Co.,
Customer Service Center.
24
(b)
(a)
Test valve in
OPEN position
Figure 11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Performer touch-n-go

Table of Contents