Weber Performer Touch-N-Go Ignition Owner's Manual page 17

Gas ignition system
Table of Contents

Advertisement

If bubbles occur, or if a bubble enlarges, the connection
is leaking. Turn OFF the gas at LP tank.
If the leak is at connection a) DO NOT OPERATE THE
BARBECUE. Contact your dealer.
If the leak is at connection b) disconnect and
reconnect the quick disconnect fitting. Turn the gas back
on and recheck with the soap and water solution.
WARNING: If leak persists after tightening the
connection, turn OFF the gas at LP tank. DO NOT
OPERATE THE BARBECUE. Contact your dealer.
After completing the leak checks:
a) Turn the LP tank valve OFF (clockwise) and rinse
connections with water.
b) Turn the test valve to the OPEN position (parallel to
the hose). Figure 12.
Test valve must be in OPEN
position when operating grill
Figure 12
Step 12
Add bowl panel, tool holders and CharBin
Storage Container
You will need: bowl panel, three tool holders and
CharBin Storage Container.
Remove protective plastic covering from bowl panel.
Slide the ends of bowl panel under bowl mounting
brackets so the ends rest on tabs inside frame. Set the
panel in place on top of the frame brace. Figure 13.
Hook the tool holders over the frame rail. There is a
cut-out on the right side of the front panel to
accommodate the tool holders. Figure 13.
(a)
Tool holders
17
Tab
Bowl panel
Figure 13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Performer touch-n-go

Table of Contents