Change of door opening direction

Should the setting-up place or handling demand it, door-
opening direction can be refitted from the right hand side
to the left hand side.
Following operations are to be done on the basis of figures
and explanations:
Pull out the plug from the mains socket.
Tilt back the appliance carefully so that the
compressor can not touch the floor. It is
recommended to ask another person for help, who can
keep the appliance at this position safely.
Unscrew the adjustable feet situated on both sides (2
pieces), in addition the screws fixing the lower door
holders (2 pieces) respectively the screw on the other
side.
Take off the freezer door by pulling it slightly
downwards.
Unscrew the top door hinge pin of the refrigerator
then screw it back on the other side.
Fit the freezer door on the upper door hinge pin.
Insert over the pin in the lower door holding plate in
the direction of the arrow.
Fix the plate on the other side leaving the position of
the door unchanged.
Then screw in the one screw in the place set free on
the other side as well as the adjustable feet (2
pieces) and stand upright again.
Place over the handles on the other side and put the
plastic covering pins supplied in the plastic bag of this
instruction book into the vacant holes.
Place the appliance back into its location, set it level
and plug it into the mains socket.
In case you do not want to perform the procedures above,
call your nearest Service Force Centre. Technicians will
accomplish the refitting expertly for a charge.

Electrical Connection

Any
electrical
required to install this
appliance should be carried out
by a qualified electrician or
competent person. This appliance
must be earthed.
The manufacturer declines any
liability should these safety
measures not be observed.

Electrical Requirements

Before switching on, make sure the electricity supply
voltage is the same as that indicated on the appliance
rating plate.
The appliance is supplied with a 13 amp plug fitted. In the
event of having to change the fuse in the plug supplied, a
13 amp ASTA approved (BS 1362) fuse must be used.
Should the plug need to be replaced for any reason. The
wires in the mains lead are coloured in accordance with
the following code:
Green and Yellow:
Blue:
Brown:
The wire coloured green and yellow must be connected to
the terminal marked with the letter "E" or by the earth
symbol
or coloured green and yellow.
The wire coloured blue must be connected to the terminal
"N" or coloured black. The wire coloured brown must be
connected to the terminal marked "L" or coloured red.
GB
work
Earth
Neutral
Live
9