Address 0 (00 hex, delivery status) disables remote communication between the RCM-810 and the bus. The module does not
appear in the system, even though it is physically connected to the CAN-bus.
2 STATUS LED
The STATUS-LED is for monitoring the communication on the CAN bus. The LED blinks rhythmically every 3
seconds, when the module's address is set to "00", which means that it is disconnected from the CAN bus
and software control. The LED blinks rhythmically in intervals of one second, when an address in the range of
01 to 250 has been assigned to the module and there has not yet been any activity on the CAN bus. As soon
as communication on the CAN bus is recognized, the LED lights for at least 100 ms, when the power
amplifier sends data on the CAN bus.
3 REMOTE CAN BUS Connection
The RCM-810 module provides two RJ-45 sockets for connecting to the REMOTE CAN BUS. These sockets
are connected in parallel and serve as inputs as well as for daisy-chaining the devices on the remote
network. Cabling in a rack system can be established using commercially available RJ-45 network cables.
However, CAN guidelines have to be observed for longer cable lengths. Both ends of the CAN-bus must be
terminated using 120 Ω terminating plugs.
The CAN bus allows using different data rates, whereas the data rate is inversely proportional to the bus
length. For smaller network setups, data rates can be as high as 500 kbit/s. For broader networks, reducing
the data rate becomes necessary (down to the minimum data rate of 10 kbit/s).
NOTE:
The data rate of the CAN bus is preset to 10 kbit/s.
The following table illustrates the relation between data rate and bus length or network size. The use of CAN repeaters is
strongly recommended for busses that exceed 1000 meters in length.
LOW
Address
0
Stand-alone
1...F
1...15
0...F
16...31
0...F
32...47
0...F
48...63
0...F
64...79
0...F
80...95
0...F
96...111
0...F
112...127
Table 4.1: CAN addresses
Transfer rate (in kbit/s) Bus length (in m)
500
250
125
62,5
20
10
Table 4.2: Transfer rate and bus length
CONTRACTOR PRECISION SERIES
HIGH
LOW
Address
8
0...F
128...143
9
0...F
144...159
A
0...F
160...175
B
0...F
176...191
C
0...F
192...207
D
0...F
208...223
E
0...F
224...239
F
0...A
240...250
F
B...F
reserved
100
250
500
1000
2500
5000
Owner's Manual
15