Electrical Connection - Candy PLE 64 Installation Manual

Advertisement

Cable connection should be done by Autorited service according to following instructions.
The electrical connection must be made according to the standards and regulations in force. Before
making the electrical connection, check the following:
Is the capacity of the electrical connections and safety fuses in the building sufficient to cope with the
load of the appliance? (Check with the adhesive info label)
Does the electricity supply line have an earth connection conforming with the standards in force?
A proper earth connection must exist in your home. If there is not a proper earth connection at your
home, please apply to an authorized technician to deal with this problem.
Is the socket or the multi-pole switch at a easily reachable point after the installation of the
appliance?
A plug conforming to standards should be connected to the mains cable and the cable should be
inserted into a safe socket.
A multi-pole switch must be used between the appliance and the electricity line if a direct electrical
connection to the appliance is required. (It must comply with standards and be appropriate for the
load)
The green-yellow ground cable must not be interrupted by a switch. The brown phase cable must
always be connected to the phase line of the mains.
The power line must be positioned so that it is not exposed to temperatures higher than 50° C.
When the power cable must be changed
appropriate to the indicated power must be used. The green-yellow ground cable should be
approximately 2 cm longer than phase and neutral cables.
Check the
electrical
connection.
The manufacturer will not accept responsibility for damages arising due to non-compliance
with the safety standards.
4 HOTPLATES
These hobs are delivered without cable. For connection, cable type and section referred to the table.

ELECTRICAL CONNECTION

only by authorized people
heaters by switching them on for 3 minutes, after having completed the
Monophase
220-240 v~
Fuse
3 G 2.5 mm
Cable - Section
H05VV-F
Cable - Type
L1
L1 : Phase
shunt 1-2
4-Neutral
T-Earth
Three-phase
380-415V2N~
25 A
2 x 16 A
2
4 G 1.5 mm
H05VV-F
1-Phase
2-Phase
4-Neutral
T-Earth
22
, a cable with a cross section
2