Temperature / Resistance Characteristics Of Ntc Control Probes (10 Kohms); Regular Maintenance Activities For Which The User Is Responsible; Maintenance Schedule - York YLCA User Manual

Air-condensed water cooling units and heat pumps
Hide thumbs Also See for YLCA:
Table of Contents

Advertisement

1
User manual
1.3

Regular maintenance activities for which the user is responsible

1.2.15 Temperature / resistance characteristics of NTC control probes (10
kOhms)
Temperature
Resistance
Temperature
[°C]
[kOhms]
-50
329,2
-49
310,7
-48
293,3
-47
277
-46
261,8
-45
247,5
-44
234,1
-43
221,8
-42
209,8
-41
198,7
-40
188,4
-39
178,3
-38
168,9
-37
160,1
-36
151,8
-35
144
-34
136,6
-33
129,7
-32
123,2
-31
117,1
-30
111,3
-29
106,7
-28
100,4
-27
95,47
-26
90,8
-25
86,39
-24
82,22
-23
78,29
-22
74,58
-21
71,07
-20
67,74
-19
64,54
-18
61,62
-17
58,66
1.3 Regular maintenance activities for which the user is respon‐
sible

1.3.1 Maintenance Schedule

The HVAC unit is designed to require as little maintenance as possible. Nevertheless, to ensure the
correct operation of the unit with a minimal use of electricity, a long working life and compliance with the
regulations of each country, regular maintenance inspections must be made.
Johnson Controls Inc. shall not be considered responsible for any damage caused by improper mainte‐
nance of the HVAC unit, which includes anything inconsistent with that described in this document or
others specifically provided with the unit.
24
Resistance
Temperature
[°C]
[kOhms]
[°C]
-16
55,95
18
-15
53,99
19
-14
50,9
20
-13
48,66
21
-12
46,48
22
-11
44,41
23
-10
42,45
24
-9
40,56
25
-8
38,76
26
-7
37,05
27
-6
35,48
28
-5
33,89
29
-4
32,43
30
-3
31,04
31
-2
29,72
32
-1
28,47
33
0
27,28
34
1
26,13
35
2
25,03
36
3
23,09
37
4
22,09
38
5
22,05
39
6
21,15
40
7
20,2
41
8
19,48
42
9
18,7
43
10
17,98
44
11
17,24
45
12
16,55
46
13
15,9
47
14
15,28
48
15
14,68
49
16
14,12
50
17
13,57
51
Resistance
Temperature
Resistance
[kOhms]
[°C]
[kOhms]
13,08
52
3,8
12,58
53
3,77
12,09
54
3,65
11,83
55
3,53
11,2
56
3,42
10,78
57
3,31
10,38
58
3,21
10
59
3,11
9,63
60
3,02
9,28
61
2,92
8,94
62
2,83
8,82
63
2,75
8,31
64
2,66
6,01
65
2,58
7,72
66
2,51
7,45
67
2,43
7,19
68
2,36
6,94
69
2,29
6,69
70
2,22
6,46
71
2,16
6,24
72
2,1
6,03
73
2,04
5,82
74
1,98
5,63
75
1,92
5,43
76
1,87
5,24
77
1,81
5,08
78
1,76
4,91
79
1,71
4,74
80
1,66
4,59
81
1,62
4,44
82
1,57
4,3
83
1,53
4,16
84
1,49
4,02
85
1,45
Temperature
Resistance
[°C]
[kOhms]
86
1,41
87
1,37
88
1,33
89
1,3
90
1,26
91
1,23
92
1,2
93
1,16
94
1,13
95
1,1
96
1,06
97
1,05
98
1,02
99
0,99
100
0,97
101
0,94
102
0,92
103
0,9
104
0,87
105
0,85
106
0,83
107
0,81
108
0,79
109
0,77

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ylca plus

Table of Contents