Adaptation To Different Types Of Gas - Electrolux EHG 6760 Instruction Booklet

Gas hob
Table of Contents

Advertisement

Adaptation to different types of gas

! ! ! ! !
Injectors replacement
Remove the pan supports.
Remove the burner's caps and crowns.
With a socket spanner 7 unscrew and remove the
injectors (Fig. 7), and replace them with the ones
required for the type of gas in use (see Table 2).
Reassemble the parts, following the same procedure
backwards.
Replace the rating label (placed near the gas supply
pipe) with the relevant one for the new type of gas
supply. You can find this label in the package of the
injectors supplied with the appliance.
Should the feeding gas pressure be different or variable
compared with the required pressure, an appropriate
pressure adjuster must be fitted on the gas supply pipe,
in compliance with the rules in force.
! ! ! ! !
Adjustment of minimum level
To adjust the minimum level of the burners, proceed as
follows:
Light the burner.
Turn the knob on the minimum position.
Remove the knob.
With a thin screwdriver, adjust the by-pass screw
(see Fig. 8). If changing from natural gas 20 mbar to
liquid gas completely tighten clockwise the by-pass
screw, until a small regular flame is obtained. If
changing from liquid gas to natural gas 20 mbar, undo
the by-pass screw about 1/2 of a turn.
Finally check the flame does not go out when quickly
turning the knob from the maximum position to the
minimum position.
This procedure can easily be carried out, anyhow the hob
has been positioned or built in the working top.
Table 2: Injectors
TYPE
TYPE OF
OF GAS
BURNER
Rapid (large)
NATURAL
GAS
Semi-rapid (medium)
Auxiliary (small)
G 20
LIQUID
Rapid (large)
GAS
Semi-rapid (medium)
(Buthane/
Auxiliary (small)
Propane)
Rapid (large)
NATURAL
Semi-rapid (medium)
GAS
Auxiliary (small)
G 20
* Natural gas G20 13 mbar for Russia only.
8
INJECTORS
NOMINAL
MARKS
POWER
1/100 mm
INPUT
k W
119
3,00
96
2,00
70
1,00
86
2,80
71
2,00
50
1,00
108
2,13
105
1,72
80
0,90
Fig. 7
Fig. 8
By-pass screw
Table 1 : BY-pass diameters
Burner
Auxiliary
Semi-rapid
Rapid
REDUCED
POWER
k W
m
0,65
0,286
0,45
0,190
0,33
0,095
0,65
0,45
0,33
0,52
0,210
0,42
0,186
0,30
0,085
Ø By-pass
in 1/100
of mm
28
32
40
NOMINAL
NOMINAL
POWER
PRESSURE
mbar
3
/h
g/h
-
-
20
-
-
202
-
144
28-30/37
-
72
-
-
13*
-