Trouble Shooting

TROUBLE SHOOTING
■ These cases are not troubles.
The following cases are not air conditioner troubles but have some reasons. You may just continue using it.
Case
Operation does not start soon.
When ON/OFF button was pressed soon
after operation was stopped.
When the mode was reselected.
Hot air does not flow out soon after the
start of heating operation.
Makes a noise.
Fizzes during HUMIDIFYING or
VENTILATING operation.
Makes a sound during HUMIDIFYING
operation.
The indoor unit makes a noise even after
HUMIDIFYING operation is stopped.
Units stops during HEATING and the
sound of running water can be heard.
The outdoor unit emits water or steam.
Mist comes out of the indoor unit.
The indoor unit gives out odor.
Cold air blows at the start of "SARARA"
DRYING operation.
The outdoor fan rotates while the air con-
ditioner is not in operation.
The operation stopped suddenly.
(Multi-colored indicator lamp is on.)
Unit stops suddenly (when in ON TIMER
mode).
Unit operates even though the multi-
colored indicator lamp is off.
Unit continues to operate even after
"SARARA" DRYING, DRY COOLING or
COOLING operation is stopped.
Room lamp flickers during HUMIDIFYING
operation.
25
This is to protect the air conditioner.
You should wait for about 3 minutes.
The air conditioner is warming up.
You should wait for 1 to 4 minutes.
■ Clicking sound can be heard either when the unit is running or stopped
This is either the sound of the valves regulating the refrigerant or the electrical parts working.
■ Sound of running water
Refrigerant is flowing through the air conditioner.
■ Blowing sound
The flow of refrigerant through the air conditioner is switching.
■ Creaking sound
The air conditioner itself is expanding or shrinking due to a change in the humidity.
■ Clopping sound
Can be heard coming from inside the air conditioner when the ventilator is on and the room
is shut. Open a window or turn off the ventilator.
■ Clicking sound can be heard either when the unit is running or stopped
This is the sound of the electrical parts working when the front panel opens or closes.
■ Blowing, cracky or burning sound
This is the sound of streamer discharging.
This is the sound of humidified or ventilated air being discharged.
The operation noise may change depending on the outdoor temperature and humidity.
■ Operation noise changes
This is because the fan for humidification moves or stops.
The fan for humidification rotates for about 3 minutes after the operation stops for product pro-
tection.
The frost on the outdoor unit is being removed. You should wait for about 3 to 10 minutes.
■ In HEATING operation
The frost on the outdoor unit melts into water or steam when the air conditioner is in defrost operation.
■ In COOLING operation
Moisture in the air condenses into water on the cool surface of outdoor unit piping and drips.
This happens when the air in the room is cooled into mist by the cold air flow during COOLING operation.
This is because moisture on the heat exchanger evaporates when "SARARA" DRYING opera-
tion is run after COOLING or DRY COOLING operation.
This happens when smells of the room, furniture, or cigarettes are absorbed into the unit and
discharged with the air flow.
(If this happens, we recommend you to have the indoor unit washed by a technician. Consult
the service shop where you bought the air conditioner.)
The outdoor odor may be captured. Stop the "URURU" HUMIDIFYING operation to eliminate
the cause of odor.
This is because the air conditioner is not warmed up.
■ After operation is stopped:
The outdoor fan continues rotating for another 60 seconds for system protection.
■ While the air conditioner is not in operation:
When the outdoor temperature is very high, the outdoor fan starts rotating for system protection.
For system protection, the air conditioner may stop operating on a sudden large voltage fluctu-
ation. It automatically resumes operation in about 3 minutes.
Reserving the on timer will cause the unit to start running up 1 hour before, in order to make
sure the temperature reaches the temperature set on the remote controller by the set time.
Using the remote controller during this time (other than the operation/stop button) will stop the
unit. Restart the unit with the remote controller.
The multi-colored indicator lamp will go off if "Monitor OFF" is set using the remote controller.
The MOLD PROOF operation will start. (If you don't want it, set to "MOLD PROOF OFF" using
the remote controller. (page 15.))
It might happen the flickers of lighting in the case of insufficient power supply.
Explanation