3.9

MAJOR SERVICE MANUAL

To obtain a service manual for your generator, con-
tact your nearest Generac Authorized Service Dealer.
Make sure to identify your MODEL NUMBER and
SERIES. Manuals can be obtained from the internet
website (www.generac.com) or a service dealer.

3.10 DRIVE BELT

The engine drives the generator rotor by means of a
pulley and drive belt arrangement. Drive belt tension
was properly adjusted before the unit was shipped
from the factory. If you suspect that drive belt tension
is incorrect, contact a Generac Authorized Service
Dealer.

3.11 EXERCISING THE GENERATOR

Generac recommends that you start and operate the
generator at least once every seven days. Let
the unit run for at least 30 minutes to "exercise"
the engine.

3.12 OUT OF SERVICE PROCEDURE

3.12.1 REMOVAL FROM SERVICE

If you cannot exercise the generator every seven days,
and it is to be out of service longer than 30 days, pre-
pare the generator for storage as follows:
1. Start the engine and let it warm up.
2. Close the fuel shutoff valve in the fuel supply line
and allow the unit to shut down.
3. While the engine is still warm from running,
drain the oil completely. Refill the crankcase with
SAE 5W-30 oil having API classification "For
Service SF ."
4. Attach a tag to the engine indicating the viscosity
and classification of the oil in the crankcase.
5. Remove the spark plug and pour two or three
tablespoons of clean, fresh engine oil into the
spark plug threaded openings. Reinstall and
tighten the spark plug.
6. Remove the battery and store it in a cool, dry
room on a wooden board. Never store the battery
on any concrete or earthen floor.
7. Clean and wipe the entire generator.
QUIETPACT 55, 65, and 75 Recreational Vehicle Generators
To return the unit to service after storage, proceed
as follows:
1. Check the tag on the engine for oil viscosity and
2. Check the state of the battery. Fill all cells of
3. Clean and wipe the entire generator.
4. Reconnect the battery. Observe battery polarity.
5. Turn OFF all electrical loads. Add fuel if neces-
6. Allow the unit to warm up thoroughly.
7. Apply electrical loads to at least 50 percent of the
8. When the engine is thoroughly warmed up, shut
9. Your generator is now ready for service.
3.13 RV GENERATOR SERVICE
QUIETPACT 55/65/75:
50 Hours ................................Clean Spark Arrestor
1st 50 Hours,
100 Hours..........................Change Engine Oil/Filter
100 Hours ..................................Clean Air Pre-filter
100 Hours ................................Inspect Spark Plugs
250 Hours ............Replace Paper Air Filter Element
400 Hours ..................................Replace Fuel Filter
500 Hours................................Replace Spark Plugs
Section 3 – Maintenance

3.12.2 RETURN TO SERVICE

classification. Verify that the correct recommend-
ed oil is used in the engine (see Section 1.5.4,
Page 6). If necessary, drain and refill with the
proper oil.
unsealed batteries to the proper level with distilled
water. DO NOT USE TAP WATER IN THE BAT-
TERY. Recharge the battery to 100 percent state of
charge, or, if defective, replace the battery.
Damage may occur if the battery is connected
incorrectly.
sary and then start the engine.
unit's rated wattage capacity.
it down.
INTERVAL
then every 500 Hours ................Adjust Valve Lash