Instructions for the Installer

Technical Data

Model Name:
EOG 601
APPLIANCE GAS SUPPLY:
APPLIANCE CATEGORY:

Cabinet Dimensions

Minimum aperture height
Minimum aperturedepth
Minimum aperture width

Important Safety Requirements

This appliance must be installed in accordance with
the Gas Safety (Installation and Use) Regulations
(current addition) and the I.E.E. Wiring Regulations.
Detailed recommendations are contained in the
following British Standard Codes of Practice - B.S. 6172,
B.S. 5440: Part 2 and B.S. 6891: Current Editions.
For appliances installed in the Republic of Ireland please
refer to NSAI- Domestic Gas Installation I.S. 813 Current
Editions and the ETCI Rules for Electrical Installations.

Provision for Ventilation

This appliance is not connected to a combustion
products evacuation device. It shall be installed and
connected in accordance with the current installation
regulations. Particular attention shall be given to the
relevant requirements regarding ventilation.
Building in

Location of appliance

The appliance may be located in a kitchen, a kitchen/
diner or bedsitting room but not in a bathroom, shower
room or bedroom.
It is essential that there is a minimum clearance of 4mm
between the top surface of the appliance and the inside
top of the cabinet. The unit must be fitted into a cabinet
conforming to dimensions given in these pages.
For appliances installed in the Republic of Ireland please
refer to NSAI- Domestic Gas Installation I.S 813 Current
Edition Section 7- Permitted Locations of Appliance.
This oven unit may be used in a Built-in or a Built-under
situation (see relevant diagrams). If the appliance is to
be built-under a hob, it is recommended that the hob be
installed before the oven unit.
14
Natural Gas G20 20mbar
II2H3+
580 mm
550 mm
560 mm
Oven
Oven Burner
Electric Grill
Oven light
Cooling fan
Total electric rating
Supply voltage (50 Hz)
The room containing the appliance should have an air
supply in accordance with BS. 5440: Part 2 Current
Edition. All rooms require an openable window or
equivalent and some rooms will require a permanent vent
as well. For room volumes up to 5m
is required; for room volumes between 5m
air vent with a minimum area of 50cm
room has a door which opens directly to the outside, no
air vent is required. For room volumes that exceed 11m
no air vent is required.
If there are other fuel burning appliances in the same
room, B.S. 5440: Part. 2: Current Editions should be
consulted to determine the requisite air vent
requirements.
For appliances installed in the Republic of Ireland please
refer to the NSAI-Domestic Gas Installation I.S. 813
Current Editions Table Four.
2,700 W (Natural gas)
2,500 W (LPG)
1,650 W
15 W
25 W
40 W
230 V
3
an air vent 100cm
2
and 10m
, an
3
3
is required. If the
2
3