24 electrolux
Connecting the terminal board
Connecting the terminal board
Connecting the terminal board
Connecting the terminal board
Connecting the terminal board
The appliance incorporates an easily
accessible 6-pole terminal board whose
jumpers (bridges) are already pre-set for
operation on 400V tri-phase with neutral
wire. In case a different mains voltage is
present, the jumpers on the terminal
board must be rearranged as shown in
the diagram. The ground cable must be
connected to terminal
connecting the supply cable to the
terminal board, secure it with a junction
clamp.
. After
FO 0330
1 2 3 4 5
230V 3~
L1
L2
1 2 3 4 5
230V 1~
L1
1 2 3 4 5
400V 2N~
L1 L2
1 2 3 4 5
400V 3N~
L1 L2 L3 N
FO 0584
L3 PE
N
PE
N
PE
PE