Abit AN8 SLI User Manual page 74

An8 series amd athlon 64/64fx system board socket 939
Table of Contents

Advertisement

3-24
mode.
!
Date (of Month) Alarm/ Time (hh:mm:ss) Alarm:
You can set the Date (month) Alarm and Time Alarm (hh:mm:ss). Any event occurring will awaken a
system that has powered down.
Cool 'n' Quiet Technology:
This option enables or disables the AMD K8 cool and quiet function.
NOTE: Please disable this item while running under SLI mode.
Power On Function:
This item selects the way you want your system to power on.
[Password]: Use a password to power on the system, select this option then press <Enter>. Enter your
password. You can enter up to 5 characters. Type in exactly the same password to confirm, and then press
<Enter>.
[Hot KEY]: Use any of the function keys between <F1> to <F12> to power on the system.
[Mouse Left]: Double click the mouse left button to power on the system.
[Mouse Right]: Double click the mouse right button to power on the system.
[Any KEY]: Use any keyboard key to power on the system.
[BUTTON ONLY]: Use only the power button to power on the system.
[Keyboard 98]: Use the power-on button on the "Keyboard 98" compatible keyboard to power on the
system.
!
KB Power On Password:
This item sets the password required in order to power on your computer. Once the password has been set,
you can only power on the system by inputting the password.
!
Hot Key Power On:
Fifteen options are available: Ctrl+F1 ~ Ctrl+F12, Power, Wake and Any Key. The default setting is
Ctrl+F1. You can choose the hot key you want to turn on computer power.
Restore on AC Power Loss:
This item selects the system action after an AC power failure.
[Power Off]: When power returns after an AC power failure, the system's power remains off. You must
press the Power button to power-on the system.
[Power On]: When power returns after an AC power failure, the system's power will be powered on
automatically.
[Last State]: When power returns after an AC power failure, the system will return to the state where you
left off before power failure occurs. If the system's power is off when AC power failure occurs, it will
remain off when power returns. If the system's power is on when AC power failure occurs, the system
will power-on when power returns.
AN8 Series
Chapter 3

Advertisement

Table of Contents
loading

This manual is also suitable for:

An8An8 v2.0An8-v

Table of Contents