Abit AN8 SLI User Manual page 56

An8 series amd athlon 64/64fx system board socket 939
Table of Contents

Advertisement

3-6
$
Voltage Monitoring:
Click <Enter> key to enter its submenu:
OC Guru
(*)CPU Core Voltage
(*)DDR Voltage
(*)DDR VTT Voltage
(*)nForce4 Voltage
(*)nForce4 Standby Voltage
(*)HyperTransport Voltage
(*)CPU VDDA 2.5V Voltage
(*)ATX +12V
(*)ATX +5V
(*)ATX +3.3V
(*)ATX 5VSB
↑↓:Move Enter:Select +/-/PU/PD:Value
All Voltages:
These items display the voltage of each element.
!
Shutdown Enable:
Use <Space> key to enable system shutdown function. If the voltage of corresponding element is
higher/lower than the high/low limit, the system would automatically shutdown.
!
Beep Enable:
Use <Space> key to enable warning beeps function. If the voltage of corresponding element is
higher/lower than the high/low limit, warning beeps will sound.
!
High/Low Limit:
These items set the high and low voltage limit.
NOTE: The value of high limit must be set above the one of low limit.
AN8 Series
µGuru Utility V1.00
ABIT EQ
Voltage
Monito ing
r
Reading Shutdow
1.550V
2.70V
1.35V
1.52V
1.50V
1.19V
2.58V
11.70V
5.03V
3.39V
5.06V
n
Beep
Enab
le
Enab
le
(*)
(*)
( )
(*)
( )
(*)
( )
(*)
( )
(*)
( )
(*)
( )
(*)
( )
(*)
( )
(*)
( )
(*)
( )
(*)
F10:Save ESC:Exit
Chapter 3
High
Low
Limit
Limit
1.89V
1.00V
2.90V
2.10V
1.55V
1.05V
1.80V
1.20V
1.85V
1.25V
1.45V
0.95V
3.00V
2.00V
14.40V 9.60V
6.00V
4.00V
3.95V
2.65V
6.00V
4.00V

Advertisement

Table of Contents
loading

This manual is also suitable for:

An8An8 v2.0An8-v