Operating Manual AV-MTD G 30 TTT
Page 10
1. After power-on "S" will be transferred to "W" if all data in "S" are reasonable.
2. In case of a storage failure "S" will be overwritten with "F", then continued as in 1.
Functions 2. and 1. will also be executed in the F reset menu function.
3. When in the menu function user store, the actual data may be stored separately.
4. When in the menu function user load, the actual setting may be overwritten with the stored
setting.
5. When in the menu function user reset, the user area is overwritten with the factory settings.