Electrical connections
Before connecting the appliance, check that the
voltage quoted on the rating plate - that is, the no-
minal voltage of the appliance - corresponds to
the available mains voltage. The rating plate can
be found on the lower housing of the ceramic
glass hob.
The mains connection must be carried out by an
D
expert electrician. The VDE-regulations and the
valid prescriptions by the local power suppy
boards have to be compiled with.
Prior to connection it should be checked whether
D
the voltage stated on the rating plate -- i.e. the
nominal voltage of the appliance and of the oven/
control box -- is identical with the prevailing mains
voltage. The rating plate is located on the lower
housing of the hob.
The heating element voltage amounts to 230 V ~.
D
The appliance will also perfectly perform with the
former mains voltage of 220 V ~.
The mains connection must be carried out in a
D
way that an all--pole insulating device is existing
with a contact opening of at least 3 mm, e.g. LS--
automatism, earth--leakage circuit--breaker or
fuse.
A wire of type H05VV-F or of higher rating is to be
D
used as supply cable.
The mains terminal is located in the bottom of the
D
appliance behind a covering slide. It can be ope-
ned with a screw driver (pict.).
According to existing mains voltage the appliance
D
has to be connected in correspondence with the
diagrams of connecting possibilities. The bridges
of the terminal board are to be changed accordin-
gly, if need be.
The protective conductor is to be connected to
D
terminal
. The protective conductor must be
longer than live leads.
The cable connections have to be connected
D
as shown and the terminal screws be firmly
tightened.
Afterwards the supply cable has to be secured by
D
strain relief device and the covering slide must be
closed by firmly pressing down until it engages.
Prior to first use remove any existing labels and
protective film from the ceramic glass plate or the
frame of the hob.
After connecting the electrical supply, all cooking
zones should be briefly switched on one after the
other at their maximum power, in order to test
whether they are operational.
Mains terminal
in the base of the hob
strain relief device
Connecting possibilities
1
2
L1
1
2
L1
1
2
L1 L2 L3
1
2
(L3)
L1
1
2
L1
Read the insstallation instructions before con-
necting th mains cable. Ensureing that the
links are fitted correctly to the terminal block
14
changing brid-
ges of the ter-
minal
3
4
5
230 V
1 L + N
N
3
4
5
400 V
2 N
2 L + N
L2
N
3
4
5
400 V
3 N
3 L + N
N
3
4
5
230 V
2 L
L2
3
4
5
230 V
3 L
L2 L3
~
~
~
2
~