Download Print this page

D-Link DMC-1001 - Power Supply - hot-plug User Manual

Redundant power supply
Hide thumbs Also See for DMC-1001 - Power Supply - hot-plug:

Advertisement

Quick Links

DMC-1001
Redundant Power Supply
User's Guide
Rev. 01 (JAN. 2002)
Printed In Taiwan
RECYCLABLE

Advertisement

loading

Summary of Contents for D-Link DMC-1001 - Power Supply - hot-plug

  • Page 1 DMC-1001 Redundant Power Supply User’s Guide Rev. 01 (JAN. 2002) Printed In Taiwan RECYCLABLE...
  • Page 2: Product Features

    NTRODUCTION Thank you for choosing the DMC-1001 Redundant Power Supply of Chassis-Based Media Converter. When the chassis is equipped with two power supplies both power supplies are switched on and share the current load. In case that one of them should fail, the other will instantaneously take 100% of the load without any loss.
  • Page 3 NSTALLATION Step 1: Connect the supplied AC power cord to the back of the chassis. Step 2: Attach the plug into a standard AC outlet with a voltage range from 100~240Vac. Step 3: Turn on the chassis system by flipping the switch beside the receptacle to ON position.
  • Page 4: Power Supply

    PECIFICATIONS Power Supply Input Voltage: 85VAC(60Hz)/264VAC(50Hz) label: 110V-240V Output +12V Voltage: Power 150 watts. (max.) Consumption Dimension 185 x 160 x 85 mm Temperature Operating: 0°~40° C, Storage: -10°~50° C Humidity Operating: 10% ~ 90%, Storage: 5% ~ 90% Overload All outputs protected from short circuit Protection condition, automatic recovery...