Install Winbond Hardware Doctor Utility
G-5
The figure below shows the warning message windows.
Ignore: You can ignore the warning message of the item this time, but it will still
pop up when the error of the same item happens again.
Disable: The chosen item will be no longer monitored thereafter, unless you
activate it in the "configuration" page.
Shutdown: Choosing this button will shutdown the computer.
Help: You can read more information and self-diagnose simple problems.
If the warning message pops up due to the wrong warning limit, you can adjust it
in the "Configuration" option. For example if you set the temperature high limit
to 40 C, you are easy to exceed proper temperature.
Please pay attention to two things when you want to make any changes in the
"Configuration" option. Firstly, you have to make sure your new setting is in the
proper range. Secondly, after you finished the configuration, you have to save it.
Otherwise, the program will start with the default value the next time.