SPECIFICATIONS· GENERATOR 1
o.on
.5KW EDT
AC GENERATOR (Single Phase)
AC GENERATOR (3 Phase)
Single Phase
Brushless, four-pole, revolving field.
Three PhaSe
Brushless, six-pole, revolving field. Sealed
Pre-lubricated, single-bearing daslgn.
10,0 KW-60 Hz
. lublicated, single-bearing design. 12 Lead
Reeonneclable, single-phase transformer
7,S KW - 50 Hz
reeonneclable for low voHage WYE, high
regulation (optional solid-state voltage
voltage Delta. Solid state voltage regulatorwtth
regulation).
protection eimuHry
Voltage
120 or 1201240 Volts - 60 Hertz
Voltage - 3 phase
Low Voltage WYE
240 Volts
230 Volts - 50 Hertz.
(60 Hertz)
High Voltage WYE
480 Volts
DELTA
240 Volts
Voltage regulation:
>5% no load to full load.
.5
Hertz
(.60%)
no load to full load.
VoHage - 3 Phase
High Voltage WYE
400 Volts
Frequency regulation:
(50 Hertz) •
DELTA
230 Volts
Rating (Volts AC)
Amperage - 3 phase
Low Voltage WYE
35 Amps
60 Hertz (1800 rpm)
120 Volts
83.3 Amps
(60 Hertz)
High Voltage WYE
IS Amps
lo,oKW
120/240 Volts
83.3/41.6 Amps
DELTA
30 Amps
50 Hartz (IS00 rpm)
230
Volts
22.6 Amps
Amperage - 3 phase
High VoHage WYE
14 Amps
7.SKW
(50 Hertz)
DELTA
24 Amps
Generator Cooling
225 - 250 elm (5.66 - 6.37 emm)
Engine Compartment
100 - 200 efm (2.83 - 5.66 emm)
Air Requirements(60 Hertz) at 1800 rpm
Generator Cooling
225 - 250 elm (5.66 - 6.37 emm)
NOTE: Increase air supply 15% for 50 Hertz opera6on (1500/pm).
Air Requirements
Engine· Compartment
(60 Hertz) at 1800 rpm
100 - 200 elm (2.83 -
5.6Itcm~I~,
NOTE: Increase air supply 15% for 50 Hertz operaUon (1500 rpm).
8.0/6.0 KW EDT
AC GENERATOR (Single Phase)
Single Phase
Voltage
Voltage regulation:
Frequency regulation:
Raling (Volts AC)
60 HedZ (1800 rpm)
8.oKW
50 Hartz (1500 rpm)
6,oKW
Generator Cooling
Air Requirements
(60 Hertz) at 1800 rpm
Brushless, four-pole, revolving field.
Pre-lubricated, single-bearing design.
Reconneclable, single-phase transformer
regulation (optional solid-state voltage
regulation).
120 or 1201240 Volts - 60 Hertz
230 Volts - 50 Hertz.
.5% no load to full load.
.5
Hertz (.60%) no load to full load.
120 Volts
66 Amps
1201240 Volts 66133 Ainps
230 Volts
22.6 Amps
175 - 200 elm (4.95 - 5.66 emm)
NOTE: Increase airsupply 15% for 50 Hertz operatIon (1500/pm).
Engine Compartment
100 - 200 elm (2;83 - 5.66 emm)
NOTE: Generator compartment ambient temperature
should not exceed l2:tF (5ifC). Forced ventilation
must be provide to maintain temperatures below this
stated temperature.
HBEKE