Operation; Startup Sequence - Montigo R520 Installation, Operation & Maintenance Manual

Indoor c-view residential fireplace
Table of Contents

Advertisement

C-View Residential R520-R620 Series Indoor Gas Fireplace
WARNING!
explosion may result causing property damage, personal injury or loss of life.
A.
Purge all air out of the gas supply line to the fireplace sys-
tem and ensure that the supply pressure is not in excess of
12" WC.
B.
Plug the electrical control panel into the power outlet. (The
power vent will start and run for about three minutes and
then turn off.
Caution: Do not turn OFF the power to this panel at this
time to operate the fireplace
1.
Turn the speed control on the right side of the panel to a low
positioning ( clockwise ).
This fireplace has been set up at the factory for a determined air volume though the venting system.
This fireplace will not operate unless the correct air movement is detected by our control system..
Please consulted with your contact person at Montigo should you have any problems with your start up.

Operation:

WARNING!
explosion may result causing property damage, personal injury or loss of life.
For Your Safety - READ BEFORE LIGHTING:
A. This appliance is equipped with an ignition system that
lights the pilot burner automatically. Do not attempt to light
the pilot by hand.
B. BEFORE LIGHTING smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
What To Do If You Smell Gas:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone
Page 20
Operation
If you do not follow these instructions exactly, a fire or

Startup Sequence:

2.
3.
4. If the right LED is not illuminated when the power vent
CAUTION!
With Honeywell Intermittent Pilot
If you do not follow these instructions exactly, a fire or
C. Do not use this appliance if any part has been under water.
Turn the wall switch to the "On" position. The LED on the
left of the panel should illuminate.
Turn the speed up on the speed control knob very slowly
until the right LED is illuminated. Note: There will be a 1/2
minute Time-On delay, then burner will fire up. This Initial
setting will produce the most attractive looking fire. How-
ever, You may increase the speed if desired.
module is running it will be a signal that the combustion air
supply is inadequate.
in your building.
Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the Fire De-
partment.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system, and
any gas control which has been under water.
f i r e f e a t u r e
Part No. XG0771 - 0070111

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

R620

Table of Contents