Installation Of Electrical Supply; Installing The Remote Switch - Montigo R520 Installation, Operation & Maintenance Manual

Indoor c-view residential fireplace
Table of Contents

Advertisement

C-View Residential R520-R620 Series Indoor Gas Fireplace

Installation Of Electrical Supply

The C-View Residential Fireplace is supplied with an external electri-
cal Control Panel pre-wired by the factory. The power control box
is connected to the fireplace with a 20 foot long 6 conductor cable
that will communicate with the fireplace.The control panel should be
located in a location that would be assessable when the fireplace in
finished.
Figure 19. (Fireplace to Control Panel Harness)
The power cord from the power vent module pugs into the side of this
panel. A 20 foot low voltage wire is attached and connected to this
panel as well. Connect a single pole On/Off switch (Black and White)
to these two wires at a location of your choice, (See Installing the
Remote Switch).
Installations in Canada must be electrically grounded in accordance
with CSA C22.1 Canadian Electrical Code Part 1 and/or Local Codes.
Installations in the USA must be electrically grounded in accordance
with local codes or, in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70-1987.
re-purge Module
dicator light
use
10V Power Supply
Wall Switch
as Control Wiring
Air Proving Switch
Control Panel / Top View
Figure 19a. (Control Panel Overview)
Page 18
Installation
Power Vent Motor
Post-purge Module
Vent Speed Control
Ignitor operation Lights
Terminal Block
Wall Switch
6 - conductor
110V Power Supply
communication
Fuse
cable
LED Indicator
Left-sideView
Figure 20. C-View Residential Power Vent Module

Installing The Remote Switch

The C-View Residential Fireplace may be connected to a wall switch
or a hand-held remote. The valve operates on a 24V circuit. DO NOT
connect the gas valve to an external circuit.
Figure 20a. (Remote Switch Wire connection)
The external electrical panel supplied with the fireplace is equipped
with a 20 foot low voltage wire, for connecting to a wall switch of your
choice. Should you require a longer switch wire, replace this wire to
any length with a wire of equal quality. Additional length are available
upon request.
CAUTION!
The valve has a 1/2 minute Time-On Delay to clear All possible
build up of burned gas within the System.
After this Time-On Delay the fireplace will proceed with the Initi-
ated Start-Up Sequence has completed.
f i r e f e a t u r e
Power Vent
Power Vent
Speed Control
Speed Control
Right-sideView
Wall Switch
Part No. XG0771 - 0070111