Control Commands Via Lan; When Web Control Administrator Rights Password Is Set (Protect Mode) - Panasonic PT-EX12KE Operating Instructions Manual

Network operations, comercial use
Hide thumbs Also See for PT-EX12KE:
Table of Contents

Advertisement

Control commands via LAN

When WEB Control administrator rights password is set (Protect mode)

Connection method
1) Obtain the IP address and port number (Initial set value = 1024) of the projector and
make a request for connection to the projector.
Acquire the IP address from the menu screen of the projector, and the port number from the WEB control
page.
IP address :
Obtain from MAIN MENU → [Network] → [Network status]
Port No. :
Acquire from the WEB control "Detailed set up" → "Command port set up" page
2) There is a response from the projector.
Response data
Data section
"NTCONTROL"
(ASCII string)
9 bytes
Mode : 1 = Protect mode
3) Generate a 32-byte hash value from the following data using MD5 algorithm.
"xxxxxx:yyyyy:zzzzzzzz"
xxxxxx :
Administrator rights user name for WEB CONTROL (Default user name is "admin1")
yyyyy :
Password of above administrator rights user (Default password is "panasonic")
zzzzzzzz :
8-byte random number obtained in Step 2
Command transmission method
Transmit using the following command format.
Transmitted data
Hash value
(See above
<Connection method>)
32 bytes
Receive data
'0'
0x30
1 byte
Error response
"ERR1"
"ERR2"
"ERR3"
"ERR4"
"ERR5"
"ERRA"
24
Blank
Mode
' '
'1'
0x20
0x31
1 byte
1 byte
Header
'0'
0x30
1 byte
Header
'0'
0x30
1 byte
Error message
Undefined control command
Out of parameter range
Busy state or no-acceptable period
Timeout or no-acceptable period
Wrong data length
Password mismatch
4 bytes
Blank
' '
(ASCII code hexadecimal
0x20
1 byte
Data section
'0'
Control command
0x30
(ASCII string)
1 byte
Undefined length
Data section
Control command
(ASCII string)
Undefined length
Random number
section
"zzzzzzzz"
number)
8 bytes
Termination symbol
(CR)
0x0d
1 byte
Termination symbol
(CR)
0x0d
1 byte
Termination symbol
(CR)
0x0d
1 byte
Termination
symbol
(CR)
0x0d
1 byte

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pt-ex12ku

Table of Contents