QuickSpecs
Configuration
HP 3PAR StoreServ 10000 Base Configurations
HP 3PAR StoreServ 10400 16GB Control/32GB Data Cache Rack Configuration Base
HP 3PAR StoreServ 10400 32GB Control/64GB Data Cache Rack Configuration Base
HP 3PAR StoreServ 10400 16GB Control/32GB Data Cache Rackmount Config Base
HP 3PAR StoreServ 10400 32GB Control/64GB Data Cache Rackmount Config Base
HP 3PAR StoreServ 10800 32GB Control/64GB Data Cache Rack Configuration Base
HP 3PAR StoreServ 10000 Controller Node Configurations
HP 3PAR StoreServ 10400 2.8-GHz 16GB Control/32GB Data Cache Controller Node
HP 3PAR StoreServ 10400 2.8GHz 32GB Control/64GB Data Cache Controller Node
HP 3PAR StoreServ 10800 2.8-GHz 32GB Control/64GB Data Cache Controller Node
HP 3PAR StoreServ 10400 2.8-GHz 16GB Control/32GB Data Cache Upg Controller Node
HP 3PAR StoreServ 10400 2.8GHz 32GB Control/64GB Data Cache Upgr Controller Node
HP 3PAR StoreServ 10800 2.8-GHz 32GB Control/64GB Data Upg Controller Node
A minimum of one (1) configuration base must be ordered
The base configuration includes two Controller Nodes, one 2-meter Cabinet, service
processor
The Rackmount Configuration Base (QR633C) includes two Controller Nodes,
rackmount kit (for backplane, controllers and service processor), service processor. A
rackmount kit must be ordered separately for each drive chassis (see Drive section
below). These rackmount kits are strictly for new installations into non-HP 3PAR
racks.
There are two 10400 base configurations available - one that includes total cache:
32GB control / 64GB data and another that includes total cache: 64GB control / 128GB
data
The 10800 base configuration includes total cache: 64GB control / 128GB data
The base configuration and node configurations, shown in the section below, have
built-in Gigabit Ethernet ports for management and Remote Copy over IP
The base configurations do not include adapters (beyond embedded ports), drive
chassis, drives, cables or expansion cabinets. These are to be ordered separately
The base configuration and expansion rack PDUs are selected based on the Country
and three phase selection option.
PDUs can be NEMA which stands for the National Electrical Manufacturers Association
or IEC which stands for the International Electrotechnical Commission
NEMA and IEC PDUs differ from each other based on Ampere ratings and the
plug types used. Generally, NEMA based PDUs are used in North America and
IEC based PDUs are used everywhere else. There are exceptions, e.g., NEMA
based PDUs are used in Japan, Taiwan and Philippines.
The NEMA PDU SKUs used are 252663-D74 for single phase and AF511A for
three phase
The IEC PDU SKUs used are 252663-B33 for single phase and AF518A for three
phase
Refer to
http://h18006.www1.hp.com/products/quickspecs/11041_div/11041_div.html
for detailed specifications regarding these PDUs
One (1) pair of Controller Nodes beyond the base configuration is supported on the
DA - 14103 Worldwide — Version 19 — January 17, 2014
HP 3PAR StoreServ 10000 Storage
QW978A
E7W33A
QR633C
E7W48A
QW979A
QR586C
E7W34A
QR638C
QR603C
E7W35A
QR640C