B
PRIMECENTER Rack
S26361-F2735-E145
RMK-F1_DI_CMA_QRL
best choice for PrimeCenter racks
consisting of
vario carrier 714-785mm
telescopic drop-in rails 781mm
with quick release lever support
with full extraction
with CMA adapter
1x per system
S26361-F4530-E11
Mounting 1U or 2U server in
asymmetrical
racks
with 1U support bracket
S26361-F2735-E71
Lateral cable management
for 2U servers or higher
- for asymmetrical racks
PRIMECENTER S2 or M1
- 1 bracket PC Rack asym.
1x per system
SNP:SY-F1647E301-P
Installation ex works for one
server or subsystem.
Hereby the rack will be delivered
completely pre-mounted and
all wired connections are tested.
With PCR M1 16U, 24U, 42U:
Systems and components
will be delivered installed in the rack
To be ordered only together with
a PRIMECENTER rack
PCR S2 e.g. S26361-K826-V10x
new PCR M1 e.g. S26361-K827-Vxxx
refer PCR S2 or M1 rack configurator
max. 1x per System
C
S26361-F2735-E175
Rack Mount Kit F1-C S7 LV
best choice for 3rd party racks
consisting of
vario carrier 559-914mm
telescopic drop-in rails 781mm
with quick release lever support
with full extraction
with CMA adapter
1x per system
S26361-F4530-E10
Mounting server in
symmetrical
racks
no support bracket needed
S26361-F2735-E82
Rack Cable Management Arm CMA 2U
for 2U Server in racks
- for symmetrical racks
M1 or 3rd party racks
Fujitsu racks
1x per system
"Rack-mounting ex factory"
This service is to be ordered once
per installable server/storage
subsystem, in order to get the
server/storage subsystem
mounted into the racks.
In case of not-installed server and subsystems
this service has to be ordered,
to get the mounting kits and the
cables installed.
PRIMERGY Classic 19" rack is not supported
Fujitsu PRIMERGY Server
System configurator and order-information guide
PRIMERGY RX300 S7
S26361-F2735-E111
No Rackmount-Kit option
Only for loose deliveries
No mounting in racks possible
max. 1x per system
C
Status 2013-12-30
Further information for
rack mounting is available
within the
Corporate Partner Portal
All "L" no's for loose delivery
S26361-F2735-L10
Adapter angle PC/DC-Rack, till 50Kg
necessary for mounting RMKs in
asymmetrical PC racks
S26361-F2735-L145
RMK-F1_DI_CMA_QRL
best choice for PrimeCenter racks
with CMA adapter
S26361-F2735-L175
RMK-F1_DI_CMA_QRL_LV
best choice for 3rd party racks
with CMA adapter
S26361-F2735-L176
RMK-F1_DI_QRL_LV
best choice for 3rd party racks
w/o CMA adapter
S26361-F2735-L7
Lateral cable management (optionally)
can only be mounted
in asymmetrical PRIMECENTER
S2 or new M1 racks in 1U above RMK
S26361-F2735-L82
Rack Cable Management Arm CMA 2U
for 2U Server in racks.
S26361-F2201-L20
Cable arm 2U PCR M1 S and 3rd p.-racks
for L176, has to be mounted above RMK
9 of 31