Problem Solver - GE Monogram ZV42 Owner's Manual

General electric stainless steel professional island range hood owner's manual
Hide thumbs Also See for Monogram ZV42:
Table of Contents

Advertisement

Questions?
Use this
problem
solver!
PROBLEM
FAN AND LIGHTS DO • The hood was never electrically connected by the installer/
NOT OPERATE WHEN
THE SWITCHES ARE
TURNED ON
THE BLOWER DOES
NOT WORK BUT
THE LIGHTS DO
THE BLOWER FAILS
TO EXHAUST THE
SMOKE/STEAM/
ODORS ADEQUATELY
The Problem Solver
POSSIBLE CAUSE
electrician/builder. Call the electrician/installer/builder to
complete the installation. This is not covered by warranty.
• A fuse may be blown or a circuit breaker tripped. Replace the fuse
or reset the circuit breaker.
• The blower motor wire harness was not connected or was not
connected properly by the installer/electrician/builder to its mating
connector located inside the hood on the top surface, to the left of
the blower assembly.
1. Switch power off at service panel and lock the service
disconnecting means to prevent power from being switched on
accidentally. When the service disconnecting means cannot be
locked, securely fasten a prominent warning device, such as
a tag, to the service panel.
2. Remove the filters and locate the blower wire harness connector.
Is it plugged into its mating connector?
3. If no, plug the blower motor connector into its mating connector
on the top of the hood. Switch the power back on. Check to see
if the fan now works.
4. If no, check the circuit breaker/fuse. If it is blown/tripped,
replace/reset it. Does the blower work now? If no, call GE
for service.
• Many factors could be the root cause for reduced air-flow.
1. Installation could be the problem: Your hood was designed to
meet specific ducting requirements. Refer to the Installation
Instructions or if you do not have them, go to ge.com.
If your duct length exceeds the manufacturer's requirements,
hood performance will suffer. Air-flow will also be reduced if the
house duct work is too small or there are too many elbows in the
system. Contact your installer or builder.
2. Obstruction in duct work could be the problem: Make sure
nothing is blocking the vent (bird nests or kinks in the duct work).
3. Damper blade may not be opening. Make sure the tape is removed
from the damper blades and that it swings open freely.
4. Damper blade on Wall or Roof Cap may not be opening. Contact
your builder so they can make sure the damper swings open freely.
5. Dirty filters/baffles—make sure filters (and all hood surfaces) are
kept clean of grease and dirt.
Professional Island Range Hood
9