Example - GE MultiLink ML1600 Instruction Manual

Ethernet communications switch
Hide thumbs Also See for MultiLink ML1600:
Table of Contents

Advertisement

CONFIGURING IGMP THROUGH THE COMMAND LINE INTERFACE

15.2.2 Example

15–8
The following example shows how to configure IGMP.
Example 15-1: Configuring IGMP
ML1600(igmp)##
set-port port=10-12 mode=forward
Port mode is set.
ML1600(igmp)##
show-port
---------------------
Port
|
Mode
---------------------
09
|
Auto
10
|
Forwarding
11
|
Forwarding
12
|
Forwarding
13
|
Auto
14
|
Auto
15
|
Auto
16
|
Auto
ML1600(igmp)##
show-router
RouterIp
---------------------------------
10.21.1.250
(continued on next page)
MULTILINK ML1600 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL
PortNo
Timer
9
25
CHAPTER 15: IGMP

Advertisement

Table of Contents
loading

Table of Contents