26
If this alert has been set up, you will see the alert
on the Daikin ENVi thermostat's screen. If you've
configured your personal Web Portal, you will also
receive an email alert.
Low Temp Limit
Select this item to set the temperature at which
the Daikin ENVi thermostat will generate a Low
Temperature Limit alert:
Disabled – No alert will be generated.
Enabled – Set temperature range of 35 to 68 °F
(1.5 to 20 °C).
High Temp Limit
Select this item to set the temperature at which
the Daikin ENVi thermostat will generate a High
Temperature Limit alert:
Disabled – No alert will be generated.
Enabled – Set temperature range of 60 to 104
°F (15.5 to 40°C).
Aux Heat Runtime Alert
If you have a heat pump with auxiliary heat
configuration, you can program the Daikin ENVi
thermostat to generate an alert if the auxiliary heat
runs for more than this programmed amount of
time during a 24-hour period.
Aux Outdoor Temp Alert
If you have a heat pump with auxiliary heat
configuration, you can also program the Daikin ENVi
thermostat to generate an alert if the auxiliary heat
is called for when the outdoor temperature exceeds
this programmed set point. (This feature requires an
Internet connection to function properly.)
(optional)
(optional)