Charcoal Filters - Electrolux EFA90950 User Manual

Hide thumbs Also See for EFA90950:
Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 1
Before carrying out any maintenance
or cleaning isolate the cooker hood
from the mains supply.

Charcoal Filters

In the recirculation mode the charcoal
filters absorb smells and unwanted
odours.
Enabling the alarm signal
• In Recirculation version Hoods, the
Filter saturation alarm can be enabled
on installation or at a later date.
• Turn the Lights and the suction Motor
off.
• Disconnect the Hood using the Main
switch or the double-pole switch on
the mains power supply.
• Restore the connection by pressing
and holding T1.
• Release the button. All five LEDs are
turned on
• Within 3 seconds press T1 until LEDs
T1 and T4 flash in confirmation:
• LED flashes twice - Activated
charcoal
filter
ENABLED
• LED flashes once - Activated
charcoal
filter
DISABLED
saturation
alarm
saturation
alarm
MAINTENANCE AND CLEANING
The filter is not washable and cannot be
reused. It must be replaced when led
S1 flashes or at least every 4 months.
The alarm signal will only light up when
the extractor motor is switched on.
To Remove/Replace the
Charcoal Filters
• Remove the metal grease filters
• Remove
the
carbon filter by releasing the fixing
hooks
• Fit the new filter by hooking it into its
seating
• Replace the metal grease filters.
This appliance can be a possible fire
hazard if the grease and charcoal fil-
ters are not cleaned and replaced as
recommended.
Alarm signal reset
• Switch off the lights and extractor
motor.
• Press button T3 for at least 3 seconds,
until the leds start to flash.