Electrolux EFA90950 User Manual page 22

Hide thumbs Also See for EFA90950:
Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 1
22 electrolux
Ducting Connection
Connect the ducting chosen to:
• the Ø150mm ducting spigot on top
of the motor housing, or the Ø150-
120mm ducting spigot item 9 and
EN
secure using the jubilee clips item 25
(not included).
• A Ø120-125mm collar item 9.1 is
provided to fit over the Ø120mm
ducting spigot when 125mm ducting
is fitted.
If the room where the cooker hood
is to be used contains a fuel burning
appliance such as a central heating
boiler, then its flue must be of the
room sealed or balanced flue type.
If other types of flue or appliances are
fitted sure that there is an adequate
supply of air to the room.
The cooker ducting (extraction mode)
must never be connected to central
heating flues, radiators or water
heaters etc.
Recirculation
The cooker hood is supplied specified
for use in the recirculation mode, with
the charcoal filter fitted.
In the recirculation mode contaminated
air is passed through the charcoal filter
to be purified and recirculated into the
kitchen through the grille outlets on
either side of the chimney.
Recirculation Connection
• Fix the connection item 15 to the
frame using the 4 screws provided.
• Fix the flange item 10 to the lower
opening of the connection item 15.
• Connect the hood air outlet to the
flange in the lower part of the junction
using a rigid or flexible ø 150 tube (by
installer's choice).
INSTALLING THE COOKER HOOD
ø 150
25
15
10
ø 125
25
9.1
9

Hide quick links: