Technical information

Technical information
Greensource
Emitted/Supplied output at +7/35º
Emitted/Supplied output at +7/45º
Heat carrier fl ow nominal
Internal pressure drop heat carrier
Air fl ow
Electrical consumption fan
Electrical supply
1)
Fuse size
Compressor
Highest outgoing heat carrier temperature
Refrigerant fi lling R-407C
HTF connection, clamping ring
Defrost system
Operating temperature
Dimensions (WxDxH)
Weight
Outer casing
Output data at +7/35º and +7/45º are stated according to the European standard EN 14511.
1)
aM type fuse, D characteristic MCB.
2)
Dimensions excl. feet, supplied min 20 mm - max 30 mm depending on adjustment.

Sound levels

The table describes the sound levels stated in sound pressure
level.
Sound pressure level:
Sound pressure level is defi ned as the sound level, which at an ear
level of 1.8 metres, is perceived one metre from the heat pump.
Measured in a sound measurement room without echo at an
outdoor temperature of +7ºC and 50ºC fl ow temperature.
Example:
When the heat pump is installed outside with free sound propaga-
tion the sound level drops by 6dBa with each doubling of distance.
kW
kW
l/s
kPa
m³/h
A
AT
ºC
kg
mm
°C
2)
mm
kg
6 kW
7 kW
5,5 / 1,5
7,1 / 2,1
5,1 / 1,7
6,9 / 2,5
0,19
0,29
5
6
2200
2200
0,44
0,44
230V 1N~
16
25
Scroll
65
65
2
2,3
Hose 1 inch internal thread
Hot gas with four-way valve
-20 – +35
820x640x1190
140
145
Galvanised enamelled plate
34
9.5 kW
8,8 / 2,3
8,5 / 2,8
0,34
7
2200
0,44
25
65
2,4
155
Sound
Heat pump
pressure level
Lp - ear (dBa)
6 kW
49
7 kW
49
9.5 kW
53
Example
Greensource 6 kW
Distance
Lp - ear (dBa)
49
1 metres
2 metres
43
4 metres
37
8 metres
31