Use only cold water. Do not use hot water supply.
7
Water Filter. Insert 1/4-in. copper or plastic water line.
a
Apply modest pull to ensure a tight fit.
Back-flow preventer valve. Insert 1/4-in. copper or plastic water line.
B
Apply modest pull to ensure a tight fit.
Connect 1/2-in. drain tube. Secure drain tube to barbed fitting with
C
hose clamp.
Shut off the water supply. Secure 1/4-in. copper or plastic water
D
feed tube.
Support weight with
clamps or ties.
1/4-in. copper
or plastic
M28682A
Water line tapping options: Refer to selected valve's literature and to local plumbing codes for
proper technique for the selected option.
Manual shutoff
valve (sold
separately)
To humidifier
From cold water supply
B
Enlarged view
Clamp
t-fitting
Water supply line
TrueSTEAM Humidification System

Water supply connectIon

D
C
1/2-in.
1/4-in. water line (plastic
drain tube
provided; copper also
acceptable)
saddle valve (provided)
5
a
M27428
To humidifier
Compression nut
Ferrule
Brass eyelet
M24852A
69-2285EFS—03