Specifications - Honeywell TrueSTEAM Professional Installation Manual

Hide thumbs Also See for TrueSTEAM:
Table of Contents

Advertisement

Available languages

Available languages

capacity:
hm512: 12 gallons per day (gpd) (45 liters per day [lpd])
hm509: 9 gpd (34 lpd)
hm506: 6 gpd (23 lpd)
humidified area:
model
cubic feet range
HM512
12000–24000
HM509
8000–18400
HM506
4000–14400
note: Higher volumes require more TrueSTEAM run
time.
Weight:
model
empty
HM512
9 lbs.
HM509
9 lbs.
HM506
8 lbs.
• Dimensions: 11-1/4 in. W x 19 in. H x 9 in. D
• Humidifier Operating Temperature Range:
34ºF–104ºF (1.1ºC–40ºC)
• Remote Hose/Nozzle Operating Temperature Range:
-50ºF–250ºF (-46ºC–121ºC)
• Operating Humidity Range: 0–95% RH, non-
condensing
drain operation
• Auto flushing is configurable to 8, 12, 20 or 30 hours
of operational time (heating element active).
• During auto flushing, cold water will enter the tank to
lower water temperature below 140ºF (60ºC) before
draining.
• During manual flush (performed by pressing the
DRAIN button) initial water temperature may be
above 140ºF (60ºC). Ensure drain outlet is not
exposed and use caution when pressing the DRAIN
button, and do NOT attempt to remove the tank with
water in it.
cautIon
Hot water temperature above 140°F (60°C)
can cause burns from scalding.
standards & approval Body requirements
Underwriters Laboratories: UL998, File no. E185662.
Federal Communications Commission: Class B compliance, File no. YU555.
Intended to be used in accordance with the National Electrical Code (NEC), ANSI/NFPA 70, and the rules of the
Canadian Electrical Code (CEC), Part 1, C22.1.
filled with Water
15 lbs.
15 lbs.
12 lbs.
TrueSTEAM Humidification System
• Flush cycle takes approximately 45 minutes to empty
the tank completely.
• Draining Temperature Range: 34ºF–212ºF
(1.1ºC–100ºC)
electrical ratings and tolerances
Input ratings
• Power Supply: 120VAC +10/ -15%, 60Hz
- HM512: 1440W at 120VAC at full load
- HM509: 1200W at 120VAC at full load
- HM506: 840W at 120VAC at full load
• HM512: 12A, 120VAC
• HM509: 10A, 120VAC
• HM506: 7A, 120VAC
• 15A, 120VAC interlock switch
• Thermostat/HVAC power monitor (R to C): 10mA
resistive at 24VAC
• Field wiring terminals: 18–22 ga. solid
• HVAC power/airflow monitor: 10 mA resistive at 24
VAC
output ratings
• Relay output contacts:
- Fan: 1.5A full load, 7.5A locked rotor at 24VAC
- Heat and Backup: 15A resistive at 120VAC
• Fill Solenoid: 0.1A at 120VAC, 0.5 PF
• Drain Solenoid: 0.1A at 120VAC, 0.5PF
• Humidistat output contacts: 10mA resistive at 24VAC
• Humidistat power supply: 100mA at 24VAC
21

specIfIcatIons

69-2285EFS—03