Output Terminal Panel Connections - MULTIQUIP MQ POWER DCA-125SSJU Operation And Parts Manual

Mq power portable generator (standard)
Table of Contents

Advertisement

DCA-125SSJU SERIES — OUTPUT TERMINAL PANEL CONNECTIONS
3Ø 480/277 UVWO Terminal Output Voltages
1. Place the voltage selector switch in the 3Ø 480/277
position as shown in Figure 27.
Figure 27. Voltage Selector Switch 480/277V
Three-Phase Position
2. Connect the load wires to the UVWO terminals as shown
in Figure 28.
Figure 28. UVWO Terminal Lugs
240/139V Three Phase Connections
3. Turn the voltage regulator knob (Figure 29) clockwise to
increase voltage output, turn counterclockwise to
decrease voltage output.
Figure 29. Voltage Regulator Knob (139V/240V)
DCA-125SSJU SERIES (STANDARD)— PARTS AND OPERATION MANUAL— REV. #4 (06/03/03) — PAGE 35
1Ø 240V/120V UVWO Terminal Output Voltages
1. Place the voltage selector switch in the 1Ø 240/120
position as shown in Figure 30.
Figure 30. Voltage Selector Switch 240/120V
2. Connect the load wires to the UVWO terminals as shown
in Figure 31.
Figure 31. UVWO Terminal Lugs
1Ø-240V/120V Connections
3. Turn the voltage regulator knob (Figure 32) clockwise to
increase voltage output, turn counterclockwise to
decrease voltage output.
Figure 32. Voltage Regulator Knob (1Ø-240/120V)
Single-Phase Position