Niles ZR-6 Installation Manual page 75

6 source, 6 zone multizone receiver with built-in am/fm tuner and ipod plug-and-play integration
Hide thumbs Also See for ZR-6:
Table of Contents

Advertisement

TROUBLESHOOTING
ZR-6 ERROR CODES
LCD Panel Message
AMP NOT HI Z
EEPROM FAULT
MULTIPLE MASTERS
MULTIPLE SLAVES
OVERLOAD
PROTECTION
THERMAL WARNING
ZONE # LSPKR OK
ZONE # LSPKR PVDD
ZONE # LSPKR SHRT
ZONE # RSPKR OK
ZONE # LSPKR PVDD
ZONE # LSPKR SHRT
POWER FAILURE # 12
POWER FAILURE # 34
POWER FAILURE # 56
SPKR WIRE ERROR # 1
SPKR WIRE ERROR # 2
SPKR WIRE ERROR # 4
SPKR WIRE ERROR # 8
SPKR WIRE ERROR # 9
NILES AUDIO CORPORATION – 1-800-BUY-HIFI – 305-238-4373
Correction
Internal Amplifier Error; Reboot System
Internal Processor Error; Reboot System
More than One Chassis Designated as Master
More than One Chassis with the Same Slave Name (1 or 2)
Speaker Load Less than 4ohm
Speaker Load Less than 4ohm
Inadequate Ventilation
Speaker Wired Correctly in a Zone with an Incorrect Speaker
Internal Amplifier Error; Reboot System
Speaker Shorted; Check Wiring
Speaker Wired Correctly in a Zone with an Incorrect Speaker
Internal Amplifier Error; Reboot System
Speaker Shorted; Check Wiring
Is a fault in either zone 1 or zone 2
Is a fault in either zone 3 or zone 4
Is a fault in either zone 5 or zone 6
PVDD over voltage fault is present
PVDD under voltage fault is present
AVDD analog fault is present
Charge-pump voltage fault is present
Combination of #1 and #8 which is usually caused by Speaker
Signal leaking to Earth/Chassis Ground