8.
TROUBLESHOOTING GUIDE:
TABLE 1 - INVERTER POWER SWITCH TURNED ON
TROUBLE/ INDICATION
No AC output –
red LED lit
No AC output –
red LED lit
No AC output –
Green LED not lit
TROUBLE/ INDICATION
Low battery alarm
sounds continuously
Low battery
alarm sounds
Motorized power tool
Motorized power tool
does not operate at
correct speed
Television/Radio
POSSIBLE CAUSE
DC input below 10 volts
Excessive appliance
load-thermal shutdown
then turn ON
Inverter fuses open
POSSIBLE CAUSE
Bad connection or wiring
Low battery voltage
Excessive start-up load
won't start
Purely inductive load
Snow in picture, buzz
interference in speaker
SUGGESTED REMEDY
Recharge or replace
battery
Reduce load-wait for
inverter to cool. Turn OFF,
Contact technical Support
toll free 866-584-5504
SUGGESTED REMEDY
Tighten all DC
connections
Recharge battery.
Remove load from
inverter while recharging
battery
If appliance does not start,
then appliance is drawing
excessive wattage and will
not work with inverter
Make the load not purely
inductive. Operate an
incandescent lamp at
same time as motor
Keep inverter and
antenna distant from
each other. Use shielded
antenna cable. Connect
antenna to amplifier
13