3000 watt continuous / 6000 watt peak converts 12 volt dc to 110 volt ac advanced mosfet technology (16 pages)
Summary of Contents for Vector MAXX SST VEC049C
Page 1
COMPACT POWER INVERTERS CONVERTS 12VDC TO 110/120VAC ADVANCED MOSFET TECHNOLOGY VEC049C VEC050C VEC051C OWNER’S MANUAL THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, OPERATION, MAINTENANCE AND STORAGE OF THIS PRODUCT. TO AVOID POSSIBLE INJURY OR PROPERTY DAMAGE, PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USING THIS PRODUCT. 4140 S.W.
IMPORTANT SAFETY INFORMATION To ensure reliable service, your power inverter must be installed and used properly. Please read the installation and operating instructions thoroughly prior to installation and use. Pay particular attention to the WARNING and CAUTION statements in this manual. The CAUTION statements advise against certain conditions and practices that may result in damage to your inverter.
INTRODUCTION Your new Vector MAXX SST inverter is one in a series of the most advanced DC to AC inverters available. With proper care and appropriate usage, it will provide years of dependable service in your car, truck, RV or boat.
FIGURE 1 – FRONT PANEL 1) THREE NORTH AMERICAN STANDARD OUTLETS 2) GREEN LED SHOWS UNIT IS OPERATING FIGURE 2 – BACK PANEL 1) HIGH SPEED COOLING FANS 2) BLACK NEGATIVE (–) TERMINAL AND RETAINING NUT 1.2 MAXX SST SAFETY FEATURES BUILT-IN AUTOMATIC SAFETY FEATURES INCLUDE: •...
2.0 INVERTER APPLICATIONS Aside from issues of supplying power to higher wattage appliances, inverters must be supplied with a constant source of high current 12VDC from a bank of batteries. At full watt load, the DC input requirements are up to 15 amps at 12VDC.
3.0 THEORY OF OPERATION MAXX SST™ inverters change 12VDC into 110/120VAC RMS, electrical power. This is accomplished in two steps. (See FIGURE 4). The first stage raises the 12VDC input to 145VDC. The advanced design of the DC-to-DC first stage uses high-frequency conversion techniques that replace bulky and heavy transformers found in older inverter technology.
NOTE: Because of wave-shape differences, using standard digital or analog voltmeters may not correctly read the inverter output voltage. Unless a true RMS voltmeter such as a "Fluke 87", "Fluke 8060A", "Beckman 4410" or "Triplet 4200" is used, the reading will be from 2 to 20 volts low. 4.0 OPERATION NOTE: Ensure that the total continuous power consumption of all tools and/or appliances connected to the inverter (and in use) does not exceed the inverter’s...
Page 10
APPLIANCE COMPUTER AND MONITOR PORTABLE VACUUM 8-CUP COFFEE MAKER ELECTRIC TRIMMER 1/2" HAMMER-DRILL RECIPROCATING SAW VACUUM CLEANER 1-1/8" ROTARY HAMMER 1/6 H.P. SUBMERSIBLE SUMP PUMP COMPACT MICROWAVE OVEN 10" BENCH SAW NOTE: APPLIANCE SPECIFICATIONS MAY VARY FROM BRAND TO BRAND. THIS TABLE IS OFFERED ONLY AS A GUIDE TO APPROXIMATE POWER RATINGS.
Inductive loads, such as TVs and stereos, require more current to operate than do resistive loads with the same wattage rating. Induction motors, as well as some TVs, may require two to six times their rated wattage to start up. Because the MAXX SST™...
ON does not reset the inverter, DO NOT ATTEMPT TO OPEN THE INVERTER. Opening the inverter, for any reason, will void the war- ranty. The unit must be returned to Vector Manufacturing, Ltd. for test- ing and repair by professional factory technicians.
FIGURE 7 is also used as a guide when the cables are measured for installing the inverter; available through Vector Technical Support toll-free at (866) 584-5504. 5.2 OPERATING ENVIRONMENT WARNINGS: DO NOT locate inverters in an area, room or compartment where explosive or flammable fumes might be present.
DC input to existing wiring (which must be approved for marine use) rated specified gauge, cable and length. (See Page 18) For cable lengths exceeding 6 feet from inverter to batteries, call Vector Manufacturing for additional installation information. The cable, fuse holder, fuse (not sup- plied) can be purchased at an electrical supply company.
A. Check all connections and tighten any loose connections. B. Ensure that the source battery has adequate charge. C. If steps A through B do not correct the problem, contact Vector Customer Service Department toll-free (866) 584-5504, for assistance. 5.5 PERMANENT INSTALLATION 5.5.1 PREPARATION FOR PERMANENT INSTALLATION...
DC wiring, so install the inverter as close as possible to the 12VDC power source. Vector inverters can be operated in any position, however, if it is to be mounted on a wall, mount it horizontally so that indicators, switches, outlets and terminal blocks on the front panel are visible and accessible.
Page 17
21. Ensure the battery has an adequate charge. If voltage is low, the cables may be too long or the gauge too light. 22. If steps 17 and 21 do not correct the problem, contact Vector Technical Support Department toll-free (866) 584-5504, for professional direction.
Replace battery fuse, if opened. Allow the inverter to cool for at least 15 minutes before attempting to start or run a high current draw device. Reduce the load on the inverter to its maximum rated output power. VECTOR MANUFACTURING, LTD...
8.2 TROUBLESHOOTING GUIDE TROUBLE/ INDICATION No AC output – red LED lit No AC output – red LED lit Low battery alarm sounds continuously Low battery alarm sounds Motorized power tool won’t start Motorized power tool does not operate at correct speed Television/radio interference...
The warranty does not extend to subsequent purchasers or users. Vector Manufacturing, Ltd. will not be responsible for any amount of damage in excess of the retail purchase price of the product under any circumstances. Incidental and consequential damages are specifically excluded from coverage under this warranty.