General Data - Saunier Duval SB30e Instructions For Use Installation And Servicing

Fanned flue system boiler
Table of Contents

Advertisement

E
D
D
E
A
B
C
450
700
300
1.1 Installation
Materials and equipment should be fit for their purpose and of
suitable quality and workmanship.
1.2 Important Notice
This boiler is for use only on natural gas, G20.
1.3 Sheet Metal Parts
WARNING. When installing or servicing this boiler care should
be taken when handling the edges of sheet metal parts to avoid
any possibility of personal injury.
1.4 Requirements
The installation of this boiler must be carried out by a competent
person in accordance with the current rules in force in the
countries of destination at the time of installation.
Manufacturer's instructions, supplied.
Manufacturer's instructions must not be taken as overriding
statutory requirements.
1.5 Data Label
The data label is on the inner case front, see diagram 1.2.
1.6 Data
See table 1 and diagrams 1.1, 1.2. & 1.3.
The Seasonal Efficiency Domestic Boilers UK (SEDBUK) is
79%.
The value is used in the UK Government's Standard Assessment
Procedure (SAP) for energy rating of dwellings. The test data
from which it has been calculated have been certified by B.S.I.

1 General Data

C
L
M
B
D
E
F
100
75
138
N
C L
C L
G
9mm
K
J
A
G
H
J
142
18
135
TABLE 1
Lift Weight
Total Weight
Gas connection
Heating and return
Safety valve
Safety valve discharge
Water content
Expansion vessel capacity 6 litres (1.32 gallons)
Heating cold fill
pressure minimum
Maximum Heating
system water
content using
fitted expansion
vessel.
Electrical supply
Electrical rating
Internal Fuse rating
Approximate gas
rate at max input
For larger systems use an additional expansion
vessel, see Section 4.
7
Optional flue kits are available
Horizontal top outlet and Vertical.
F
H
K
L
M
110
138
85
EXTD.
30Kgs (66Ibs)
39.5Kgs (88Ibs)
Ø 15mm compression
Ø 22mm compression
Preset 3bar (43.5lbf/in
Ø 15mm copper
1.17 litres (.26 gallons)
0.7bar
(10.1lbf/in
60 litres
(13.2 gallons)
with a cold
fill pressure
of 0.7bar
230V~50Hz
150W fused 3A
1) Type T2A
3.06m
3
/h
(108.2ft
Diagram 1.1
N
115
103
EASYFIT
2
)
2
)
3
/h)
221872B