DRAINING

Protection against freezing
If the boiler is to be out of use for any long periods
during
severe
weather
recommended that the whole system, including the
boiler, be drained to avoid the risk of freezing.
If in doubt, consult your servicing company.
The ECOSY boilers have a built in frost protection
device that protects the boiler from freezing. If the
boiler is to be left and there is a risk of frost, ensure
that the gas and electrical supplies are left
connected and that the ON/OFF switch is left in the
ON position.The frost protection device will switch
the pump when the temperature of the boiler water
falls below 7 C and light the boiler when the
temperature falls below 3 C. When the temperature
reaches 10 C, the boiler stops. The pump will run
again 15 minutes.

SERVICING/MAINTENANCE

To ensure the continued efficient and safe opera-
tion of the boiler, it is recommended that it is
checked and serviced at regular intervals. The fre-
quency of servicing will depend upon the installa-
tion conditions and usage but, in general, once a
year should be enough.
conditions,
it
is
Note: This device works irrespective of any room
thermostat setting and only protects the boiler.
Always ensure that adequate frost protection is
given to the entire system where necessary.
Draining and filling
Caution: The boiler is installed as part of a sealed
system which must only be drained and filled by a
competent person.
Heating safety valve
CAUTION: A safety valve with a discharge pipe is
fitted to these boilers.
The valve MUST NOT BE TOUCHED except by a com-
petent person. If the valve discharges at any time,
switch the boiler off and isolate it from the electrical
supply. Contact your installation/service company.
Cleaning
The boiler casing can be cleaned with a damp cloth
followed by a dry cloth to polish.
Do not use abrasive or solvent cleaners.
Boiler casing
CAUTION. Do not remove or adjust the casing in any
way, as incorrect fitting may result in faulty opera-
tion. If in