Remote 14 Receptacle Information - Unitor UWI 400 Owner's Manual

Arc welding power source 380/440 volt model
Hide thumbs Also See for UNITOR UWI 400:
Table of Contents

Advertisement

4-9. Remote 14 Receptacle Information

A
J
K
I
B
C L N
H
M
D
G
F
E
*The remaining sockets are not used.
Notes
24 VOLTS AC
115 VOLTS AC
REMOTE
OUTPUT
CONTROL
A/V
AMPERAGE
VOLTAGE
ST-801 192
GND
Socket*
Socket Information
A
24 volts AC. Protected by supplementary protect-
or CB2.
B
Contact closure to A completes 24 volts AC con-
tactor control circuit.
I
115 volts AC. Protected by supplementary pro-
tector CB1.
J
Contact closure to I completes 115 volts AC con-
tactor control circuit.
C
Output to remote control; 0 to +10 volts DC, +10
volts DC in MIG mode.
D
Remote control circuit common.
E
0 to +10 volts DC input command signal from re-
mote control.
H
Voltage feedback; +1 volt DC per 10 output recep-
tacle volts.
F
Current feedback; +1 volt DC per 100 amperes.
M
CC/CV select
G
Circuit common for 24 and 115 volts AC circuits.
K
Chassis common.
OM-202 137 Page 19