4-6. Dimensions And Weight

Hole Layout Dimensions
A
11-3/4 in. (298 mm)
B
1-11/16 in. (42 mm)
C
15-3/4 in. (400 mm)
D
19-3/32 in. (485 mm)
E
8-11/16 in. (221 mm)
F
1-17/32 in. (39 mm)
G
1/4-20 UNC -2B thread
Weight
76 lb (34.6 kg)

4-7. Selecting a Location

!
Do not move or operate unit
where it could tip.
Location
18 in.
(460 mm)
A
E
F
D
C
B
Movement
1
4
18 in.
(460 mm)
24 in.
G
(610 mm)
12-1/2 in.
(318 mm)
804 801-A
1
1
Use handles to lift unit.
2
Use cart or similar device to move
unit.
3
Locate unit near correct input
power supply.
!
2
17 in.
(432 mm)
Lifting Handles
Hand Cart
Line Disconnect Device
Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.
Ref. ST-151 556 / 801 192