Specification
Type Of Output
Welding Processes
Overall Dimensions
Rated Weld Output
Type Of Input Power
Input Amperes At Rated Output
Input Amperes While Idling
KVA/KW Used At Rated Output
KVA/KW Used While Idling
Max. Open-Circuit Voltage
Weight
2-1. Volt-Ampere Curve
SECTION 2 – SPECIFICATIONS
Table 2-1. Welding Power Source
Direct Current/Constant Voltage (DC/CV)
Shielded Metal Arc (SMAW), Gas Metal Arc (GMAW), Flux Cored Arc (FCAW), Gas Tungsten Arc
Welding (GTAW), Air Carbon Arc (CAC-A) Gouging, Stress Relieving, Resistance Heating
See Figure 3-3
1000 Amp
1000 Amperes, 76 Volts DC At 100% Duty Cycle
(See Section 2-2)
Three-Phase; 230, 460, Or 575 Volts AC; 60 Hz
224 A At 230 V, 112 A At 460 V, 90 A At 575 V
8 A At 230 V, 4 A At 460 V, 3.2 A At 575 V
89 kVA/85 kW
3.2 kVA/0.96 kW
85 Volts DC
Net: 896 lb (406 kg); Ship 986 lb (447 kg)
Figure 2-1. Volt-Ampere Curve
Description
1500 Amp
1500 Amperes, 76 Volts DC At 100% Duty Cycle
(See Section 2-2)
Three-Phase; 230, 460, Or 575 Volts AC; 60 Hz
334 A At 230 V, 167 A At 460 V, 134 A At 575 V
10.8 A At 230 V, 5.4 A At 460 V, 4.3 A At 575 V
131 kVA/133 kW
4.3 kVA/1.3 kW
85 Volts DC
Net: 1068 lb (484 kg); Ship 1158 lb (525 kg)
The volt-ampere curve shows the
voltage and amperage output capa-
bilities of the welding power source.
ssb1.1* 10/91 – SB-047 999-A
OM-267 Page 9