6. ELECTRICAL DATA

6-1. Electrical Characteristics

Indoor Unit
CS-KS12NB41 & CZ-18BT1U
Outdoor Unit CU-KS12NK1A
Cooling
Performance at
Rating conditions
Rating conditions:
Indoor air temperature:
Outdoor air temperature:
Running amp.
A
Power input
W
80 °F (26.7 °C) DB / 67 °F (19.4 °C) WB
95 °F (35 °C) DB
Indoor Unit
Outdoor Unit
Fan Motor
Fan Motor + Compressor
115V Single-phase 60Hz
0.21
18
34
Complete Unit
12.39
1,242
12.6
1,260